Morphometric analysis in three-dimensional intracoronary ultrasound: an in vitro and in vivo study performed with a novel system for the contour detection of lumen and plaque.

نویسندگان

  • C von Birgelen
  • C Di Mario
  • W Li
  • J C Schuurbiers
  • C J Slager
  • P J de Feyter
  • J R Roelandt
  • P W Serruys
چکیده

Currently, automated systems for quantitative analysis by intracoronary ultrasound (ICUS) are restricted to the detection of the lumen. The aim of this study was to determine the accuracy and reproducibility of a new semiautomated contour detection method, providing off-line identification of the intimal leading edge and external contour of the vessel in three-dimensional ICUS. The system allows cross-sectional and volumetric quantification of lumen and of plaque. It applies a minimum-cost algorithm and the concept that edge points derived from previously detected longitudinal contours guide and facilitate the contour detection in the cross-sectional images. A tubular phantom with segments of various luminal dimensions was examined in vitro during five catheter pull-backs (1 mm/sec), and subsequently 20 diseased human coronary arteries were studied in vivo with 2.9F 30 MHz mechanical ultrasound catheters (200 images per 20 mm segment). The ICUS measurements of phantom lumen area and volume revealed a high correlation with the true phantom areas and volumes (r = 0.99); relative mean differences were -0.65% to 3.86% for the areas and 0.25% to 1.72% for the volumes of the various segments. Intraob-server and interobserver comparisons showed high correlations (r = 0.95 to 0.98 for area and r = 0.99 for volume) and small mean relative differences (-0.87% to 1.08%), with SD of lumen, plaque, and total vessel measurements not exceeding 7.28%, 10.81%, and 4.44% (area) and 2.66%, 2.81%, and 0.67% (volume), respectively. Thus the proposed analysis system provided accurate measurements of phantom dimensions and can be used to perform highly reproducible area and volume measurements in three-dimensional ICUS in vivo.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computerized assessment of coronary lumen and atherosclerotic plaque dimensions in three-dimensional intravascular ultrasound correlated with histomorphometry.

Intravascular ultrasound (IVUS), which depicts both lumen and plaque, offers the potential to improve on the limitations of angiography for the assessment of the natural history of atherosclerosis and progression or regression of the disease. To facilitate measurements and increase the reproducibility of quantitative IVUS analyses, a computerized contour detection system was developed that dete...

متن کامل

Reconstruction and quantification with three-dimensional intracoronary ultrasound. An update on techniques, challenges, and future directions.

Conventional two-dimensional intracoronary ultrasound enables the extent, distribution, and therapy of atherosclerotic plaques to be studied as it provides a unique tomographic visualization of both the vascular lumen and wall'". The most important limitation of two-dimensional intracoronary ultrasound in pre/poststudies is the matching of the target sites for serial measurement. This problem i...

متن کامل

A New Computer-Aided Detection System for Pulmonary Nodule in CT Scan Images of Cancerous Patients

Introduction: In the lung cancers, a computer-aided detection system that is capable of detecting very small glands in high volume of CT images is very useful.This study provided a novelsystem for detection of pulmonary nodules in CT image. Methods: In a case-control study, CT scans of the chest of 20 patients referred to Yazd Social Security Hospital were examined. In the two-dimensional and ...

متن کامل

In vitro and in vivo evaluation of a novel testosterone transdermal delivery system (TTDS) using palm oil base

Objective (s): Transdermal preparations for testosterone are becoming popular because of their unique advantages such as avoidance of first-pass effect, convenience, improved bioavailability, and reduction of systemic side effects. A novel testosterone transdermal delivery system (TDDS) was developed using a palm oil base called HAMINTM (a commercial product) and tested using in vitro and in vi...

متن کامل

The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report

Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American heart journal

دوره 132 3  شماره 

صفحات  -

تاریخ انتشار 1996