Device for continuous urine collection in the newborn.

نویسندگان

  • R J Lund
  • H B Valman
  • A Platt
چکیده

Sir, I read the detailed description given by Lund et al.1 with great interest. Two years ago, while studying very preterm babies, I began to use an almost identical system. Since then I have made several modifications which have increased its versatility, simplified the changing of the slings, and greatly improved its acceptability for use with very small and immature subjects (Figure). As our nursery is equipped with three different kinds of incubator it is inconvenient to use apparatus which matches the fittings of only one particular model. I therefore designed a Perspex tray, 62 x 33 cm, which can replace the mattress in the base of any incubator. A double slope was made to keep the apparatus shallow (height 75 cm) so that the baby remained in the normal nursing position within the incubator, and at the same time provided a sufficiently steep angle in the base of the tray for efficient urine drainage. Each end of the apparatus base consisted of a shallow Perspex 'valley' which sloped from either side at an angle of 150; the central V was 3.5 cm below the top of the tray at either end and sloped lengthways towards the centre of the apparatus at 50, reaching a drainage tube where the ends met. This arrangement gave excellent urine drainage despite the fairly shallow lengthways slope, as the urine tended to form a small rivulet in the central groove. In any case the flow could still be increased by using the incubator base tipping mechanisms which were not obstructed. The most convenient arrangement was to lead the drainage tube out of the incubator through one of the

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Weighing wet diapers: a new approach to measuring infant output.

Accurate measurement of fluid losses is important in infant patients, especially in burn cases. Indwelling catheters, urine collection bags and other commonly used methods of continuous urine collection and measurement have several disadvantages including trauma, danger of infection, skin irritation, need for restraints, and use of expensive devices. The present study was designed to ascertain ...

متن کامل

Alternative methods for newborn urine sample collection.

PURPOSE To investigate the accuracy of laboratory results of urine samples collected from cotton balls as compared with paired samples collected from catheterization, Preemie Pampers, and Newborn Pampers. METHOD Urine samples were collected from 30 infants by aspirating urine from a cotton ball placed over the meatus. An additional urine sample was obtained from the same infants by aspiration...

متن کامل

Device for continuous urine collection in the newborn

study could have resulted from inadvertent introduction of CHD during umbilical catheterisation. However, the absence of such levels in other infants from Study B, who underwent invasive procedures, suggests that accidental introduction of CHD can be avoided and that the occasional use of an ethanol CHD solution for topical antisepsis in preterm infants need not result in high plasma CHD concen...

متن کامل

An easy technique for removal of knotted catheter in the bladder: percutaneous suprapubic cystoscopic intervention.

Uncontaminated urine samples are indispensable to precisely diagnose urinary tract infections in new-borns or infants. Among many clinical interventions for urine collection are described, the most common noninvasive practice is using sterile bags, associated with significant contamination of samples. In children, however, invasive methods i.e. catheterization, are generally needed for reliable...

متن کامل

Urinary tract infection in full-term newborn infants: value of urine culture by bag specimen collection.

OBJECTIVE To evaluate the efficacy of urine culture by bag specimen for the detection of neonatal urinary tract infection in full-term newborn infants. Retrospective study (1997) including full-term newborn infants having a positive urine culture (> 100,000 CFU/ml) by bag specimen collection. The urinary tract infection diagnosis was confirmed by positive urine culture (suprapubic bladder aspir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of disease in childhood

دوره 57 4  شماره 

صفحات  -

تاریخ انتشار 1981