Non-Intrusive Temperature Measurements Using Microscale Visualization Techniques

نویسندگان

  • Pramod Chamarthy
  • S V. Garimella
  • Steven T. Wereley
  • Suresh V. Garimella
چکیده

μPIV is a widely accepted tool for making accurate measurements in microscale flows. The particles that are used to seed the flow, due to their small size, undergo Brownian motion which adds a random noise component to the measurements. Brownian motion introduces an undesirable error in the velocity measurements, but also contains valuable temperature information. A PIV algorithm which detects both the location and broadening of the correlation peak can measure velocity as well as temperature simultaneously using the same set of images. The approach presented in this work eliminates the use of the calibration constant used in the literature (Hohreiter et al. 2002) [1], making the method system-independent, and reducing the uncertainty involved in the technique. The temperature in a stationary fluid was experimentally measured using this technique and compared to that obtained using the particle tracking thermometry method (PTT) and a novel method, low image density PIV (LID-PIV). The method of cross-correlation PIV was modified to measure the temperature of a moving fluid. A standard epi-fluorescence μPIV system was used for all the measurements. The experiments were conducted using spherical fluorescent polystyrene-latex particles suspended in water. Temperatures ranging from 20oC – 80oC were measured. This method allows simultaneous non-intrusive temperature and velocity measurements in integrated cooling systems and lab-on-a-chip devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microscale Laser-Induced Fluorescence Method for Non-Intrusive Temperature Measurement

Ratiometric Laser Induced Fluorescence (LIF) Thermometry is applied for temperature measurements in a ‘T’ junction, using microscale visualization methods. Rhodamine B (RhB) and Rhodamine 110 (Rh110) are used as the temperature-dependent and temperature-independent dye, respectively. The temperature responses of the two dyes were carefully measured for different concentrations. A novel normaliz...

متن کامل

Non-intrusive temperature measurement using microscale visualization techniques

The ‘‘nano-particle image velocimetry’’ technique uses evanescent-wave illumination generated by total internal reflection at the wall to excite colloidal neutrally buoyant fluorescent tracer particles. The displacement of these particles over time as they are convected by the flow then gives the flow velocity components tangential to the wall. Since the extent of the illumination region normal...

متن کامل

Measurement of the temperature non-uniformity in a microchannel heat sink using microscale laser-induced fluorescence

Ratiometric laser induced fluorescence (LIF) thermometry is developed as a tool for temperature measurements using microscale visualization methods. Rhodamine B (RhB) and Rhodamine 110 (Rh110) are used as the temperature-dependent and temperature-independent dyes, respectively. The temperature responses of the two dyes are carefully measured as a function of concentration. The traditional twody...

متن کامل

Advanced Laser Spectroscopy in Combustion Diagnostics

In recent years, a large number of linear and nonlinear laser-based diagnostic techniques for non-intrusive measurements of species concentrations, temperatures, and gas velocities in a wide pressure and temperature range with high temporal and spatial resolution were developed and have become extremely valuable tools to study many aspects of combustion. Nonlinear laser spectroscopic techniques...

متن کامل

Non-Intrusive Distress Signal Detection using Image Processing

Intrusive systems have the ability to achieve desired results of distressing using various methods like heart beat measurement, temperature sensing, humidity sensing, blood pressure measurements etc. but these systems have a major drawback of being intrusive. However, an efficient non-intrusive system which could replace the above mentioned systems can be developed with the help of image proces...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015