Matched Comparison of Two Different Biological Prostheses for Complete Supra-annular Aortic Valve Replacement.
نویسندگان
چکیده
Objective The aim of this retrospective study was to evaluate the hemodynamic performance of the St. Jude Medical Trifecta (SJM Trifecta; St. Jude Medical, St Paul, Minnesota, United States) and the Carpentier-Edwards Perimount Magna Ease (CEPM Ease; Edwards Lifesciences, Irvine, California, United States) bioprostheses early postoperative and at 1 year. Methods From October 2007 to October 2008, a total of 61 consecutive patients underwent aortic valve replacement (AVR) with the CEPM Ease prosthesis. From a prospective cohort of 201 patients (March 2011 to January 2012) who received AVR with the SJM Trifecta valve, a matched group of 51 patients was selected. Matching was conducted 1:1 by ejection fraction, gender, age, and body surface area. A Hegar dilator was used to define the aortic tissue annulus diameter. Data were grouped on the basis of the patient's tissue annulus diameter (≤22 mm; 23-24 mm; ≥25 mm). Results Early postoperative and at 1 year mean pressure gradients (MPGs) in the various groups ranged from 7.2 ± 4.6 to 7.1 ± 2.4 mm Hg and from 10.0 ± 4.3 to 8.0 ± 2.8 mm Hg in the SJM Trifecta group and from 18.0 ± 5.0 to 12.1 ± 3.6 mm Hg and from 17.7 ± 4.5 to 11.8 ± 3.2 mm Hg in the CEPM Ease group, respectively. Likewise, effective orifice areas (EOAs) ranged from 1.7 ± 0.5 to 2.0 ± 0.5 cm(2) and from 1.5 ± 0.3 to 1.7 ± 0.4 cm(2) in the SJM Trifecta group and from 1.3 ± 0.5 to 1.9 ± 0.5 cm(2) and from 1.2 ± 0.3 to 1.8 ± 0.3 cm(2) in the CEPM Ease group, respectively. A marked left ventricular mass (LVM) regression across all annulus sizes was noted in both groups. Severe patient-prosthesis mismatch (PPM) was infrequent overall. Conclusion The SJM Trifecta valve showed lower MPGs early postoperative and at 1 year as well as higher EOA and effective orifice area index early postoperative. No significant differences were detected with regard to LVM regression and PPM.
منابع مشابه
Hemodynamic comparison of bioprostheses for complete supra-annular position in patients with small aortic annulus.
OBJECTIVES The present study evaluates complete supra-annular bioprostheses in patients with an aortic annulus of 18 to 23 mm in diameter. BACKGROUND Aortic valve replacement in patients with small aortic annulus using stented bioprostheses is often associated with unsatisfactory hemodynamic results and high incidence of patient-prosthesis mismatch. METHODS Between February 2000 and January...
متن کاملUpdate of the European standards for inactive surgical implants in the area of heart valve prostheses.
OBJECTIVE The approval of a heart valve for the European market takes place in accordance with European and international standards. A new version of the EN Standards was published in June 2006, which responded to different technical innovations in the area of heart valve technology. This work outlines the differences between the new EN ISO 5840 (2005) and the old EN 12006-1 (1999). METHODS W...
متن کاملComparison of eight prosthetic aortic valves in a cadaver model.
OBJECTIVES Proper valve selection is critical to ensure appropriate valve replacement for patients, because implantation of a small valve might place the patient at risk for persistent gradients. Labeled valve size is not the same as millimeter measure of prosthetic valve diameters or the annulus into which it will fit. Studies that use the labeled valve size in lieu of actual measured diameter...
متن کاملThe Freedom SOLO valve: superior hemodynamic results with a new stentless pericardial valve for aortic valve replacement.
BACKGROUND AND AIM OF THE STUDY The new Freedom SOLO aortic valve, as a modification of the Pericarbon Freedom stentless valve, requires only one suture line. The study aim was to compare both prostheses with regard to surgical convenience and early postoperative hemodynamics. METHODS In this case-matched study, 90 patients underwent primary elective isolated or combined aortic valve replacem...
متن کاملComparison of Clinical Outcomes Seprate and semi continus sewing methods during and after Heart valves Surgery
Background and Aims: Various therapies and surgeries are applied in heart valve surgery, including interrupted and semi-continuous suture techniques. Therefore, this study aimed to compare the clinical implications of two methods of interrupted and semi-continuous suture techniques during and after mitral or aortic valve replacement surgery among patients referred to Department of Surgery, Scho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Thoracic and cardiovascular surgeon
دوره 63 6 شماره
صفحات -
تاریخ انتشار 2015