Usefulness of 11C-methionine positron emission tomography for detecting intracranial ameloblastic carcinoma: A case report

نویسندگان

  • AKIRA TEMPAKU
  • YOSHINOBU TAKAHASHI
  • HIDETOSHI IKEDA
  • SHIGERU YAMAUCHI
  • TAKASHI GOTOH
  • NOBUYUKI BANDOH
  • SYUJIROU MAKINO
  • TAKUJI SHIMADA
  • HAJIME KAMADA
چکیده

Ameloblastic carcinoma, secondary type, is an extremely rare odontogenic malignant tumor. The present study reports the case of a 58-year-old male with ameloblastic carcinoma that extended into the intracranial space close to the internal carotid artery. Surgical excision was performed, as headaches were being caused via compression by the mass. Small remnants of the tumor remained surrounding the internal carotid artery following surgical resection. Although the remnant tissue was not detected on magnetic resonance imaging or 18F-fluorodeoxyglucose (FDG)-positron emission tomography (PET), it was clearly visualized on 11C-methionine PET in the early post-operative follow-up period. No neurological deficits were exhibited during the follow-up period, and 11C-methionine PET was able to detect the remnant lesion distribution in the intracranial space. The current study presents a rare case of ameloblastic carcinoma that extended into the intracranial space. In addition, several diagnostic imaging tools were compared in order to determine the most suitable imaging modality. At present, the patient is continuing a therapeutic course of radiation and evident mass reduction has been observed. However, the therapeutic effects are currently under consideration. To the best of our knowledge, this is the first study on the effectiveness of using 11C-methionine PET for detecting ameloblastic carcinoma with intracranial extension.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cortical dysplasia localized by [11C]methionine positron emission tomography: case report.

Numerous functional neuroimaging techniques have progressively been added to the presurgical evaluation of refractory partial epilepsies. These investigations can help confirm the origin of seizure onset previously suggested by MR imaging and electro-clinical data, provide independent prognostic information, and provide critical diagnostic value when MR imaging results are strictly normal or sh...

متن کامل

Diagnosis of Brain Tumors Using Amino Acid Transport PET Imaging With 18F- Fluciclovine: A Comparison Study With L-Methyl-11C-Methionine PET Imaging

Objective(s): 18F-fluciclovine (trans-1-amino-3-[18F] fluorocyclobutanecarboxylic acid, [FACBC]) is an artificial amino acid radiotracer used for positron emission tomography (PET) studies, which is metabolically stable in vivo and has a long half-life. It has already been shown that FACBC-PET is useful for glioma imaging. However, there have been no reports evaluating the efficiency of FACBC-P...

متن کامل

Clinical positron emission tomography for brain tumors: comparison of fludeoxyglucose F 18 and L-methyl-11C-methionine.

PURPOSE To evaluate the differences between fludeoxyglucose F 18 (FDG) and L-methyl-11C-methionine (11C-methionine) as tracers for positron emission tomography (PET) in the evaluation of brain tumors. METHODS We analyzed 10 patients with histologically verified cerebral glioma or meningioma and 1 patient with a neuroradiologic diagnosis of low-grade glioma by using FDG, 11C-methionine, and PE...

متن کامل

Radiation-induced medulloblastoma in an adult: a functional imaging study.

We describe functional imaging findings using MRI, 1H-Magnetic resonance spectroscopy and positron emission tomography in a case of radiation-induced medulloblastoma following radiotherapy for pineal gland tumor. MRS showed a prominent choline peak; FDG, 11C-Met and 11C-Choline PET showed a minimal glucose, increased methionine and choline uptake.

متن کامل

Quantitative evaluation of L-[methyl-C-11] methionine uptake in tumor using positron emission tomography.

Tumor uptake of L-[methyl-11C]methionine ([11C]Met) was assessed in six patients with brain tumors and three patients with lung cancer using positron emission tomography (PET). In arterial plasma samples taken at 5, 15, 30, and 60 min after injection, a fraction of [11C]Met was measured using high performance liquid chromatography in individual patients. Employing curve fitting, a history of [1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2014