Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX - RAdiation Dose study (RAD-MATRIX).
نویسندگان
چکیده
BACKGROUND Radiation absorbed by interventional cardiologists is a frequently under-evaluated important issue. Aim is to compare radiation dose absorbed by interventional cardiologists during percutaneous coronary procedures for acute coronary syndromes comparing transradial and transfemoral access. METHODS The randomized multicentre MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX) trial has been designed to compare the clinical outcome of patients with acute coronary syndromes treated invasively according to the access site (transfemoral vs. transradial) and to the anticoagulant therapy (bivalirudin vs. heparin). Selected experienced interventional cardiologists involved in this study have been equipped with dedicated thermoluminescent dosimeters to evaluate the radiation dose absorbed during transfemoral or right transradial or left transradial access. For each access we evaluate the radiation dose absorbed at wrist, at thorax and at eye level. Consequently the operator is equipped with three sets (transfemoral, right transradial or left transradial access) of three different dosimeters (wrist, thorax and eye dosimeter). Primary end-point of the study is the procedural radiation dose absorbed by operators at thorax. An important secondary end-point is the procedural radiation dose absorbed by operators comparing the right or left radial approach. Patient randomization is performed according to the MATRIX protocol for the femoral or radial approach. A further randomization for the radial approach is performed to compare right and left transradial access. CONCLUSIONS The RAD-MATRIX study will probably consent to clarify the radiation issue for interventional cardiologist comparing transradial and transfemoral access in the setting of acute coronary syndromes.
منابع مشابه
Efficacy of Radial Versus Femoral Access in the Acute Coronary Syndrome: Is It the Operator or the Operation That Matters?
In the recently published MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX) trial, the use of transradial access (TRA) compared to transfemoral access (TFA) during percutaneous coronary intervention (PCI) for acute coronary syndrome (ACS) was associated with a reduction in net adverse cardiovascular events. However, the results of M...
متن کاملRadiation exposure in relation to the arterial access site used for diagnostic coronary angiography and percutaneous coronary intervention: a systematic review and meta-analysis.
BACKGROUND Transradial access for cardiac catheterisation results in lower bleeding and vascular complications than the traditional transfemoral access route. However, the increased radiation exposure potentially associated with transradial access is a possible drawback of this method. Whether transradial access is associated with a clinically significant increase in radiation exposure that out...
متن کاملTransradial versus transfemoral artery approach for coronary angiography and percutaneous coronary intervention in the extremely obese.
OBJECTIVES This study sought to evaluate the safety and efficacy of transradial versus transfemoral access for coronary angiography and percutaneous coronary intervention in patients with a body mass index ≥ 40 kg/m(2). BACKGROUND Coronary angiography is most commonly performed via femoral artery access; however, the optimal approach in extremely obese (EO) patients remains unclear. METHODS...
متن کاملCoronary Angiography Safety between Transradial and Transfemoral Access
Background and Aim. The aim of study was to evaluate safety, feasibility, and procedural variables of transradial approach compared with transfemoral approach in a standard population of patients undergoing coronary catheterization as one of the major criticisms of the transradial approach is that it takes longer overall procedure and fluoroscopy time, thereby causing more radiation exposure. M...
متن کاملA Randomized Comparison of the Transradial and Transfemoral Approaches for Coronary Artery Bypass Graft Angiography and Intervention
Methods Consecutive patients (N 1⁄4 128) having previously undergone CABG surgery and referred for cardiac catheterization were randomized to radial or femoral access. The primary study endpoint was contrast volume. Secondary endpoints included fluoroscopy time, procedure time, patient and operator radiation exposure, vascular complications, and major adverse cardiac events. Analyses were by in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Cardiovascular revascularization medicine : including molecular interventions
دوره 15 4 شماره
صفحات -
تاریخ انتشار 2014