Comparison of Pressures Applied by Digital Tourniquets in the Emergency Department
نویسندگان
چکیده
BACKGROUND Digital tourniquets used in the emergency department have been scrutinized due to complications associated with their use, including neurovascular injury secondary to excessive tourniquet pressure and digital ischemia caused by a forgotten tourniquet. To minimize these risks, a conspicuous tourniquet that applies the least amount of pressure necessary to maintain hemostasis is recommended. OBJECTIVE To evaluate the commonly used tourniquet methods, the Penrose drain, rolled glove, the Tourni-cot and the T-Ring, to determine which applies the lowest pressure while consistently preventing digital perfusion. METHODS We measured the circumference of selected digits of 200 adult males and 200 adult females to determine the adult finger size range. We then measured the pressure applied to four representative finger sizes using a pressure monitor and assessed the ability of each method to prevent digital blood flow with a pulse oximeter. RESULTS WE SELECTED FOUR REPRESENTATIVE FINGER SIZES: 45mm, 65mm, 70mm, and 85mm to test the different tourniquet methods. All methods consistently prevented digital perfusion. The highest pressure recorded for the Penrose drain was 727 mmHg, the clamped rolled glove 439, the unclamped rolled glove 267, Tourni-cot 246, while the T-Ring had the lowest at 151 mmHg and least variable pressures of all methods. CONCLUSION All tested methods provided adequate hemostasis. Only the Tourni-cot and T-Ring provided hemostasis at safe pressures across all digit sizes with the T-Ring having a lower overall average pressure.
منابع مشابه
Pressures secondary to circumferential digital dressings in clay models
The hands and fingers are common sites of injury, accounting for an estimated 4.8 million injured persons treated in US hospital emergency departments in 2001 alone. Three million of these injuries involved one or more fingers, of which 1.3 million (44%) were diagnosed as finger lacerations.[1] To minimize the morbidity associated with these injuries, digital tourniquets are necessary to provid...
متن کاملControlled hypotension and minimal inflation pressure: a new approach for pneumatic tourniquet application in upper limb surgery.
UNLABELLED Minimal inflation pressures are recommended for limb surgery to eliminate complications attributable to high inflation pressures with the pneumatic tourniquets. We applied controlled hypotension and a minimal inflation pressure (CHAMIP) technique to provide a bloodless surgical field. Thirty-six patients scheduled for upper extremity surgery were randomized equally to receive either ...
متن کاملMeasurement of hazardous pressure levels and gradients produced on human limbs by non-pneumatic tourniquets
This paper reports on existing and novel transducers for improved quantitative investigations of the levels of applied pressures and pressure gradients produced on human limbs by non-pneumatic tourniquet straps, and by non-pneumatic elastic bandages and elastic rolls when used as tourniquets, for comparison to benchmark data for pneumatic tourniquet cuffs commonly used in surgery at present.
متن کاملSurvival with emergency tourniquet use to stop bleeding in major limb trauma.
OBJECTIVE The purpose of this study was to determine if emergency tourniquet use saved lives. SUMMARY BACKGROUND DATA Tourniquets have been proposed as lifesaving devices in the current war and are now issued to all soldiers. Few studies, however, describe their actual use in combat casualties. METHODS A prospective survey of injured who required tourniquets was performed over 7 months in 2...
متن کاملA Comparison of Patients Absorption Doses with Bone Deformity Due to the EOS Imaging and Digital Radiology
Background: This study has aimed to measure the patient dose in entire spine radiography by EOS system in comparison with the digital radiography. Methods: EOS stereo-radiography was used for frontal and lateral view spine imaging in 41 patients in a prospective analytical study. A calibrated dose area product (DAP) meter was used for calibration of the DAP in EOS system. The accuracy and pr...