Guide wire migration during femoral vein catheterization.

نویسندگان

  • Mohammad Reza Khatami
  • Rozita Abbasi
  • Gelareh Sadigh
چکیده

Central vein catheterization is a routine and relatively safe procedure in critically ill patients. Complications with this procedure depend to the site of catheterization and the skill of the operator. In addition to the common complications with femoral vein catheterization there are some rare usually preventable side effects related to guide wire and catheter. In our patient who underwent femoral catheterization for acute hemodialysis, we report migration of guide wire through the systemic circulation from the femoral vein to the jugular vein. This is a very rare complication that is a human error and is totally preventable by doing the procedure by a skilled doctor and considering the standards described for central vein catheter insertion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Loss of Guide Wire: A Rare Complication of Intra-Aortic Balloon Pump Insertion

At the final stages of a coronary artery bypass graft operation on a 64-year-old man, an experienced physician attempted to insert an intra-aortic balloon pump into the femoral artery via the Seldinger technique. However, while the balloon pump was being passed over the guide wire, the latter was completely lost. The guide wire should be held at the tip at all times to prevent passage into the ...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

Breakage of DHS guide wire during surgery and its migration into the pelvis through the hip joint is a rare complication and its removal can be very challenging for the surgeon. We share our experience of a similar case wherein we used an ‘iliofemoral’ approach to successfully remove the broken transfixing guidewire from the hip joint. Although iliofemoral approach is similar to the lateral win...

متن کامل

Intrapelvic Protrusion of a Broken Guide Wire Fragment during Fixation of a Femoral Neck Fracture

  During fixation of a femoral neck fracture in a 23-year-old male patient with cannulated screws, a broken guide wire fragment inadvertently advanced through the hip joint and protruded into the pelvis. A second surgical approach was needed to remove the broken fragment from the pelvis. Awareness of such a potentially devastating complication will make surgeons more cautious during implementa...

متن کامل

Extra Luminal Entrapment of Guide Wire; A Rare Complication of Central Venous Catheter Placement in Right Internal Jugular Vein.

Central venous Catheterization (CVC) is a commonly performed procedure for venous access. It is associated with several complications. We report a rare case of extra luminal entrapment of guide wire during CVC placement in right jugular vein. We report a case of 28 years old female patient presented in our emergency with history of entrapped guide wire in right side of neck during CVC. X-ray sh...

متن کامل

Unusual site of guide-wire entrapment during central venous catheterization.

We are reporting a case of possible entrapment of guide wire in the region of tricuspid valve, which made it impossible to remove the guide wire from internal jugular (IJ) vein for a short while. Awareness about this rare complication is emphasized.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Iranian journal of kidney diseases

دوره 4 4  شماره 

صفحات  -

تاریخ انتشار 2010