Comparison of skinfold thicknesses and bioelectrical impedance analysis with dual-energy X-ray absorptiometry for the assessment of body fat in patients on long-term haemodialysis therapy.

نویسندگان

  • Maria Ayako Kamimura
  • Carla Maria Avesani
  • Miguel Cendoroglo
  • Maria Eugênia Fernandes Canziani
  • Sérgio Antônio Draibe
  • Lilian Cuppari
چکیده

BACKGROUND Body composition assessment in patients with chronic renal failure is of paramount importance since studies have demonstrated the association of protein-energy malnutrition with an increased morbidity and mortality in this population. However, practical and sensible indicators of body compartments are still needed for clinical purposes. Thus, we aimed to evaluate the simple methods of skinfold thicknesses (SKF) and bioelectrical impedance analysis (BIA), using dual-energy X-ray absorptiometry (DEXA) as a reference method, for the assessment of body fat in patients on long-term haemodialysis therapy. METHODS We studied 30 clinically stable patients (15 men/15 women) undergoing haemodialysis at the Dialysis Unit of the Federal University of São Paulo. Body fat assessment was performed by the SKF, BIA and DEXA methods after a haemodialysis session. Analysis of variance, intra-class correlation coefficient and Bland and Altman plot analysis were used for comparative analysis among the methods. RESULTS Body fat estimates by SKF (17.7 +/- 7.8 kg) and BIA (18.6 +/- 9.2 kg) were not significantly different from those obtained by DEXA (18.2 +/- 7.9 kg) considering the whole population. However, the BIA technique worked differently from DEXA when analysed by gender, measuring less fat content in men and higher fat content in women (P < 0.01). No differences were observed for SKF. Strong intra-class correlation coefficients (r) were found between DEXA with SKF (r = 0.94) and BIA (r = 0.91). DEXA showed a relatively good agreement with both SKF [0.47 +/- 2.8 (-5.0 to 6.0) kg] and BIA [-0.39 +/- 3.3 (-6.9 to 6.1) kg] in all patients according to the Bland and Altman plot analysis. However, considering gender, BIA showed greater mean prediction error of 1.93 +/- 2.5 (-3.0 to 6.8) kg for men and -2.71 +/- 2.3 (-7.2 to 1.8) kg for women. CONCLUSIONS The simple and long established method of SKF was preferable over BIA, which showed gender-specific variability in the assessment of body fat in patients undergoing haemodialysis. However, more comparative and longitudinal studies are needed to evaluate the applicability of these practical methods for monitoring body composition in the routine care of patients with chronic renal failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Toward body composition reference data for infants, children, and adolescents.

Growth charts for weight and height have provided the basis for assessment of children's nutritional status for over half a century, with charts for body mass index (BMI) introduced in the 1990s. However, BMI does not provide information on the proportions of fat and lean mass; and within the past decade, growth charts for children's body composition have been produced by using techniques such ...

متن کامل

Comparison of bioelectrical impedance with skinfold thickness and X-ray absorptiometry to measure body composition in HIV-infected with lipodistrophy.

INTRODUCTION Human immunodeficiency vírus (HIV)-associated lipodystrophy syndrome (LS) includes body composition and metabolic alterations. Lack of validated criteria and tools make difficult to evaluate body composition in this group. OBJECTIVE The aim of the study was to compare different methods to evaluate body composition between Brazilians HIV subjects with (HIV+LIPO+) or without LS (HI...

متن کامل

Estimation of body composition from bioelectrical impedance of body segments: comparison with dual-energy X-ray absorptiometry.

In twenty-eight healthy subjects, ten men and eighteen women, with a range in body mass index (BMI) of 17.9-31.6 kg/m2 and an age range 20-60 years, body composition was estimated by dual-energy X-ray absorptiometry (DEXA), skinfold anthropometry (SFA) and bioelectrical impedance analysis (BIA) of the 'whole body' and body segments. In thirteen subjects muscle mass was also estimated by 24 h ur...

متن کامل

New bioelectrical impedance formula for patients with respiratory insufficiency: comparison to dual-energy X-ray absorptiometry.

Malnutrition in patients with severe respiratory insufficiency can lead to severe complications, justifying the use of objective nutritional assessment techniques, such as bioelectrical impedance analysis (BIA), which is an easy, noninvasive method of measuring body composition. The purpose of this study was to develop, and validate against dual-energy X-ray absorptiometry (DXA), a BIA formula ...

متن کامل

Comparison of body composition analysis methods in clinical routine.

BACKGROUND Skinfold thickness (SFT) and bioelectrical impedance (BIA) are readily available and commonly used techniques in patient monitoring for body composition analysis (BCA) in clinical practise. Another one, dual-energy X-ray absorptiometry (DEXA) method became popular in body composition analysis (BCA) in recent years. Its results have been reported to be quite accurate and precise, in c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 18 1  شماره 

صفحات  -

تاریخ انتشار 2003