In Vivo Bioimpedance Spectroscopy Characterization of Healthy, Hemorrhagic and Ischemic Rabbit Brain within 10 Hz–1 MHz
نویسندگان
چکیده
Acute stroke is a serious cerebrovascular disease and has been the second leading cause of death worldwide. Conventional diagnostic modalities for stroke, such as CT and MRI, may not be available in emergency settings. Hence, it is imperative to develop a portable tool to diagnose stroke in a timely manner. Since there are differences in impedance spectra between normal, hemorrhagic and ischemic brain tissues, multi-frequency electrical impedance tomography (MFEIT) shows great promise in detecting stroke. Measuring the impedance spectra of healthy, hemorrhagic and ischemic brain in vivo is crucial to the success of MFEIT. To our knowledge, no research has established hemorrhagic and ischemic brain models in the same animal and comprehensively measured the in vivo impedance spectra of healthy, hemorrhagic and ischemic brain within 10 Hz-1 MHz. In this study, the intracerebral hemorrhage and ischemic models were established in rabbits, and then the impedance spectra of healthy, hemorrhagic and ischemic brain were measured in vivo and compared. The results demonstrated that the impedance spectra differed significantly between healthy and stroke-affected brain (i.e., hemorrhagic or ischemic brain). Moreover, the rate of change in brain impedance following hemorrhagic and ischemic stroke with regard to frequency was distinct. These findings further validate the feasibility of using MFEIT to detect stroke and differentiate stroke types, and provide data supporting for future research.
منابع مشابه
Ex-Vivo Characterization of Bioimpedance Spectroscopy of Normal, Ischemic and Hemorrhagic Rabbit Brain Tissue at Frequencies from 10 Hz to 1 MHz
Stroke is a severe cerebrovascular disease and is the second greatest cause of death worldwide. Because diagnostic tools (CT and MRI) to detect acute stroke cannot be used until the patient reaches the hospital setting, a portable diagnostic tool is urgently needed. Because biological tissues have different impedance spectra under normal physiological conditions and different pathological state...
متن کاملInvestigation the frequency of asymptomatic hemorrhagic transformation of infarction in CT scan of acute ischemic stroke patients
Background: Asymptomatic hemorrhagic transformation infarct (AHTI) is known as a complication of ischemic attack and maybe occurs in the entire stroke. However, the role of AHTI in the result of the treatment is still not clear, because it is based on the definition of an asymptomatic and not identifiable. The aim of this study was assessment and evaluation frequency of AHTI in acute ischemic s...
متن کاملVisualizing transplanted muscle flaps using minimally invasive multi-electrode bioimpedance spectroscopy
We describe here an imaging system that uses bioimpedance spectroscopy with multi-electrode array to indicate the state of muscle flap regions under the array. The system is able to differentiate between different health states in the tissue and give early information about the location and size of ischemic sub-regions. The array will be 4*8 electrodes with the spacing of 5mm between the electr...
متن کاملThe Evaluation and Comparison of Oxidative Stress in Hemorrhagic and Ischemic Stroke
Background: Among different mechanisms, oxidative stress has a possible role in neural injury in cerebrovascular events. Objectives: Assessment the oxidants-antioxidants imbalance in ischemic and hemorrhagic strokes. Materials and Methods: Serum level of malondialdehyde, the main marker of lipid peroxidation, and total antioxidant capacity were measured in a group of 48 stroke patients consis...
متن کاملBioimpedance Assessment of Oral Squamous Cell Carcinoma with Clinicopathological Correlation.
AIM Molecular alterations at membrane, cytosol and nuclear level in cancer cells/tissue show variations in bioimpedance measure. In the present study, bioimpedance assessment and comparison was investigated between oral squamous cell carcinoma (OSCC) and normal tissue. Study further involves clinicopathological correlation of bioimpedance values in OSCC. MATERIALS AND METHODS The present stud...
متن کامل