Verification of Utility Requirements on Modern Numerical Transformer Protection by Dynamic Simulation
نویسندگان
چکیده
Power utilities are aware of the specific characteristics and requirements for their network. For this reason, they may require additional functionality from the protective devices and secondary systems included in their power network. Therefore ECEPA requires a number of specific tests to be conducted on the protection system proposed for a particular application to prove the suitability of the proposed protection system for the specific application, as in Xiang (1). Only when all of these tests are successfully passed, the protection system is certified for use in ECEPA’s network. The 500/230kV autotransformers are extremely important power transmission elements in ECEPA’s network. Most of these autotransformers consist of three single-phase transformer units. Protection systems for these autotransformers have to fulfil very strict requirements, which are set down by the utility.
منابع مشابه
Determination of a new model to study ultra-saturation phenomenon during the loaded power transformer energization and its effect on differential protection
One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...
متن کاملSelection of Current Transformers & Wire Sizing in Substations
More and more sub-stations are retrofitted with numerical relays, meters and monitoring devices. Most often, the older relay gets replaced with a newer relay with the rest of the installation such as Current Transformer (CT) and lead remaining undisturbed. Utilities have standardized on their older current transformers and want to maintain the same current transformer specifications throughout ...
متن کاملDetermination of a new model to study ultra-saturation phenomenon during the loaded power transformer energization and its effect on differential protection
One of transient phenomenon that causes the mal-operation of the power transformer differential protection during the energization of a loaded power transformer is the ultra-saturation phenomenon. In this paper, a new model for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the pow...
متن کاملTransformer Life Enhancement Using Dynamic Switching of Second Harmonic Feature in IEDs
Energization of a transformer results in sudden flow of current which is an effect of core magnetization. This current will be dominated by the presence of second harmonic, which in turn is used to segregate fault and inrush current, thus guaranteeing proper operation of the relay. This additional security in the relay sometimes obstructs or delays differential protection in a specific scenario...
متن کاملA New Model for Analysis of Unusual Mal-Operation of Differential Protection Due to the Ultra-Saturation Phenomenon during the Loaded Power Transformer Energization
In this paper, a new model based on the thevenin equivalent circuit for investigating the ultra-saturation phenomenon during the energization of a loaded power transformer is presented and its effect on the differential protection of the transformer is considered. The ultra-saturation phenomenon causes the mal-operation of the power transformer differential protection. So, the description a...
متن کامل