Array lead zirconate titanate/glass piezoelectric microcantilevers for real-time detection of Bacillus anthracis with 10 spores/ml sensitivity and 1/1000 selectivity in bacterial mixtures.

نویسندگان

  • John-Paul McGovern
  • Wei-Heng Shih
  • Richard F Rest
  • Mitali Purohit
  • Mark Mattiucci
  • Kambiz Pourrezaei
  • Banu Onaral
  • Wan Y Shih
چکیده

An array of three identical piezoelectric microcantilever sensors (PEMSs) consisting of a lead zirconate titanate layer bonded to a glass layer was fabricated and examined for simultaneous, in situ, real-time, all-electrical detection of Bacillus anthracis (BA) spores in an aqueous suspension using the first longitudinal extension mode of resonance. With anti-BA antibody immobilized on the sensor surfaces all three PEMS exhibited identical BA detection resonance frequency shifts at all tested concentrations, 10-10(7) spores/ml with a standard deviation of less than 10%. The detection concentration limit of 10 spores/ml was about two orders of magnitude lower than would be permitted by flexural peaks. In blinded-sample testing, the array PEMS detected BA in three samples containing BA: (1) 3.3x10(3) spores/ml, (2) a mixture of 3.3x10(3) spores/ml and 3.3x10(5) S. aureus (SA) and P. aeruginosa (PA) per ml, and (3) a mixture of 3.3x10(3) spores/ml with 3.3x10(6) SA+PA/ml. There was no response to a sample containing only 3.3x10(6) SA+PA/ml. These results illustrate the sensitivity, specificity, reusability, and reliability of array PEMS for in situ, real-time detection of BA spores.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Selectivity of Piezoelectric-excited Millimeter-sized Cantilever (pemc) Sensors to Bacillus Anthracis Spores in the Presence of Bacillus Thuringiensis and Bacillus Cereus Spores in a Flow Cell

We report a highly sensitive, rapid and reliable method for the detection of Bacillus Anthracis spores at 300/mL using a piezoelectric-excited millimeter-sized cantilever (PEMC) sensor. Antibody specific to Bacillus anthracis (BA, Sterne strain 7702) spores was immobilized on PEMC sensors, and exposed to spores (300 to 3x10 spores/mL). The resonant frequency decreased at a rate proportional to ...

متن کامل

Microresonator mass sensors for detection of Bacillus anthracis Sterne spores in air and water.

Towards the goal of developing a real-time monitoring device for microorganisms, we demonstrate the use of microcantilevers as resonant mass sensors for detection of Bacillus anthracis Sterne spores in air and liquid. The detection scheme was based on measuring resonant frequency decrease driven by thermally induced oscillations, as a result of the added mass of the spores with the use of a las...

متن کامل

Application of the real-time PCR for the detection of airborne microbial pathogens in reference to the anthrax spores.

To establish the rapid detection method of airborne bacterial spores, we examined Bacillus anthracis spores by real-time PCR. One hundred liters of air were trapped on a filter of an air monitor device. After it was suspended in PBS, spores of B. anthracis were artificially added. The suspension was also heated at 95 degrees C for 15 min and used for real-time PCR using anthrax-specific primers...

متن کامل

Gamma irradiation can be used to inactivate Bacillus anthracis spores without compromising the sensitivity of diagnostic assays.

The use of Bacillus anthracis as a biological weapon in 2001 heightened awareness of the need for validated methods for the inactivation of B. anthracis spores. This study determined the gamma irradiation dose for inactivating virulent B. anthracis spores in suspension and its effects on real-time PCR and antigen detection assays. Strains representing eight genetic groups of B. anthracis were e...

متن کامل

Determination of anthrax foci through isolation of Bacillus anthracis form soil samples of different regions of Iran

To isolate and detect anthrax spores form soil in different regions of Iran in order to find the anthrax foci‚ a total of 668 environmental specimens were collected during 2003-2004. Bacterial endospores were extracted from soil specimens via flotation in distilled water, incubation at room temperature, filtration, heat shock and culture on blood agar and selective PLET media. Bacillus anthraci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 80 12  شماره 

صفحات  -

تاریخ انتشار 2009