Mercury Thin Film at Glassy Carbon Electrode for Adsorptive Stripping Voltammetric Determination of Captopril in Pharmaceutical Samples
نویسندگان
چکیده
A simple square-wave adsorptive voltammetric (SWAV) method was developed for determining Captopril (CAP) in pharmaceutical formulations. The proposed method was based on the electrochemical reduction of CAP at a mercury thin film electrode (MTFE). The preparation of the TMFE/Glassy carbon electrode was very simple; also, this electrode had very good reproducibility and regeneration of its surface was very easy. This kind of electrode has the advantages of mercury electrode and a negligible amount of mercury. In this study, the MTFE in situ produced on glassy carbon electrode to the adsorptive voltammetric quantification of trace amount of CAP. MTFE was shown to be extremely useful for the voltammetric measurements of CAP at μM level. Under optimized conditions, the SW adsorptive stripping voltammetric peak current showed linear correlation with drug concentration over the range of 4.6–64.5 μM with the correlation coefficient of 0.992. The detection limit at the S/N ratio of 3 was 0.6 μM for CAP (n=6) and the relative standard deviation for 23 μM of CAP (n=6) was 6.9%. The film electrode had the advantages of acceptable sensitivity, reproducibility, and simple preparation. The MTFE applied to determination of CAP in tablet samples with satisfactory results. KeywordsGlassy carbon electrode, Thin mercury film, Captopril, Voltammetric determination Analytical & Bioanalytical Electrochemistry 2015 by CEE www.abechem.com Anal. Bioanal. Electrochem., Vol. 7, No. 3, 2015, 344-357 345
منابع مشابه
Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes
An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...
متن کاملAdsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes
An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...
متن کاملNew, Simple and Sensitive Voltammetric Procedure for Determination of Paracetamol in Pharmaceutical Formulations
A new, simple and sensitive adsorptive stripping voltammetric procedure for determination of paracetamol at a lead film glassy carbon electrode modified with Nafion film (Nafion/PbF/GCE) in pharmaceutical formulations was described. Deposition of lead film on a glassy carbon electrode from 0.1 mol L-1 HNO3 at the potential of -1.4 V was performed. The Nafion film coating was carried out by appl...
متن کاملSquare-wave adsorptive stripping voltammetric determination of nanomolar levels of bezafibrate using a glassy carbon electrode modified with multi-walled carbon nanotubes within a dihexadecyl hydrogen phosphate film.
A highly sensitive method for bezafibrate determination using a glassy carbon electrode (GCE) modified with multi-walled carbon nanotubes within a dihexadecyl hydrogen phosphate film based on square-wave adsorptive stripping voltammetry (SWAdSV) is proposed. The electrochemical behaviour of bezafibrate has been studied by cyclic voltammetry, showing an irreversible anodic peak at a potential of...
متن کاملStripping voltammetric determination of palladium, platinum and rhodium in freshwater and sediment samples from South African water resources.
Stripping voltammetry as technique has proved to be very useful in the analysis of heavy and other metal ions due to its excellent detection limits and its sensitivity in the presence of different metal species or interfering ions. Recent assessments of aquatic samples have shown increased levels of platinum group metals (PGMs) in aquatic ecosystems, caused by automobile exhaust emissions and m...
متن کامل