Effects of Rogowski Coil and Covered-conductor Parameters on the Performance of Pd Measurements in Overhead Distribution Networks

نویسندگان

  • G. Murtaza Hashmi
  • Matti Lehtonen
چکیده

An on-line single-phase partial discharge (PD) measuring system using Rogowski coil is simulated in EMTP/ATP for the monitoring of falling trees on coveredconductor (CC) overhead distribution lines. The simulation results are compared with those obtained from the laboratory measurements. The effect of Rogowski coil terminating impedance is analysed for the performance of PD measuring system. The proposed model can be used to estimate the length of the practical CC lines at which PDs due to falling trees can be detected; thus, deciding the number and positioning of the sensors over a particular length of the CC lines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling of Rogowski Coil for On-line Pd Monitoring in Covered- Conductor Overhead Distribution Networks

In this paper, EMTP/ATP simulation environment is used to model the Rogowski coil for partial discharge (PD) monitoring due to leaning trees on the covered-conductor (CC) overhead distribution lines. The simulations are performed to obtain the Rogowski coil response at different lengths of the CC line and the results are compared with those obtained from the laboratory measurements. The results...

متن کامل

Experimental Evaluation of Rogowski Coil Performance for Locating PD in Energized Overhead Covered-Conductor Feeder

An experimental analysis is performed to evaluate Rogowski coil performance for PD (partial discharge) location on overhead CC (covered-conductor) distribution lines. The measuring set-up is arranged in high voltage laboratory. A multi-end measuring method is chosen as a technique to locate PD source point on the line. A power transformer is used to energize one end of the CC line by the AC vol...

متن کامل

Partial Discharge Location Technique for Covered-Conductor Overhead Distribution Lines

Aalto University, P.O. Box 11000, FI-00076 Aalto www.aalto.fi Author Muzamir Isa Name of the doctoral dissertation Partial Discharge Location Technique for Covered-Conductor Overhead Distribution Lines Publisher School of Electrical Engineering Unit Department of Electrical Engineering Series Aalto University publication series DOCTORAL DISSERTATIONS 9/2013 Field of research Power Systems and H...

متن کامل

Design Modification of Rogowski Coil for Current Measurement in Low Frequency

The principle object of this paper is to offer a modified design of Rogowski coil based on its frequency response. The improvement of the integrator circuit for nullifying the phase difference between the waveforms of the measured-current and the corresponding terminal voltage is a further object of this investigation. This paper addresses an accurate, yet more efficient measuring and protect...

متن کامل

Design, Implementation and Simulation of Non-Intrusive Sensor for On-Line Condition Monitoring of MV Electrical Components

Non-intrusive measurement technology is of great interest for the electrical utilities in order to avoid an interruption in the normal operation of the supply network during diagnostics measurements and inspections. Inductively coupled electromagnetic sensing provides a possibility of non-intrusive measurements for online condition monitoring of the electrical components in a Medium Voltage (MV...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008