A Novel Osseous Densification Approach in Implant Osteotomy Preparation to Increase Biomechanical Primary Stability, Bone Mineral Density, and Bone-to-Implant Contact.
نویسندگان
چکیده
PURPOSE It is essential to have sufficient bone bulk and density at the implant site in order to achieve good bone-to-implant contact and primary stability, which are crucial for osseointegration. A new osteotomy preparation technique was recently introduced that uses a bone preservation method that creates a layer of compacted bone along the surface of the osteotomy. The hypothesis of this study was that this novel technique would increase primary implant stability, bone mineral density, and the percentage of bone at the implant surface compared with drilling technique. MATERIALS AND METHODS A total of 72 osteotomies were created in porcine tibial plateau bone samples using three preparation techniques: standard drilling; osseous extraction drilling with a new tapered, multi-fluted bur design; and osseous densification with the same multi-fluted bur rotating in a reversed direction that preserved and created a compacted layer of bone. The surgical process (temperature increase, drilling force, and torque), mechanical stability during the insertion and removal of 4.1-mm and 6.0- mm diameter implants (implant torque and stability quotient), and bone imaging (scanning electron microscopy, microcomputed tomography measurement of bone mineral density, and histomorphology) were compared among the three preparation techniques. RESULTS Osseous densification significantly increased insertion and removal torques compared to standard drilling or extraction drilling. No significant differences in implant stability quotient readings or temperature increases were demonstrated among the three groups. Although the same bur was used for extraction drilling and osseous densification techniques, the osseous densification osteotomy diameters were smaller than both the extraction drilling and standard drilling osteotomies due to the spring-back effect of bone elastic strain created. Imaging methods documented a layer of increased bone mineral density around the periphery of osseous densification osteotomies. The percentage of bone at the implant surface was increased by approximately three times for implants prepared with osseous densification compared with standard drilling. CONCLUSION This study confirmed the hypothesis that the osseous densification technique would increase primary stability, bone mineral density, and the percentage of bone at the implant surface compared with drilling. By preserving bulk bone, it is hypothesized that the healing process will be accelerated due to the bone matrix, cells, and biochemicals that are maintained in situ and autografted along the surface of the osteotomy site. The healing response requires further study in vivo.
منابع مشابه
Effect of Implant Site Preparation by Piezoelectric and Conventional Drilling on Autograft Cell Viability: A Clinical Trial
Background and Aim: Implant site preparation with minimal trauma is an important factor in success of implant treatment and has a great effect on osseointegration. Piezoelectric bone surgery was introduced as a modern technique for micrometric osteotomy with precise, controllable action. Preservation of osteoblast cell viability is critical to achieve successful osseointegration. The present st...
متن کاملتحلیل پایداری ایمپلنت دندانی و بررسی تاثیر عوامل موثر بر اتصال ایمپلنت- استخوان به کمک مدل اصطکاکی تماس
Background and Aims: Relative displacement of the implant with respect to bone and quality of bone-implant contact play critical roles in the dental implant stability. The goal of this study was to investigate the dental implant stability using non-linear finite elements method. Therefore, bone-implant relative displacement due to applied force to the implant was calculated, and then an appropr...
متن کاملبررسی رابطه بین دانسیته استخوانی حاصل ازCone-Beam Computed Tomography با میزان ثبات اولیه ایمپلنت دندانی
Introduction & Objective: Study of bone quality before treatment is very important. The aims of this study were to assess bone quality with density values obtained by cone-beam computed tomography (CBCT) and to determine the correlations between bone density and primary stability of dental implants. Materials & Methods: In this experimental in vitro study 32 implants were inserted into fresh ...
متن کاملComparison of Implant Stability in Sinus Lift Surgery Using Autogenous Versus Allogeneic Bone Grafts
Background and aim: The most common method of increasing implant stability in the posterior maxilla comprises the reinforcement of bone height using bone grafts in sinus lift surgery. The purpose of the present study was to compare autogenous and allogeneic bone grafts in implant stability after open sinus lift surgery. Materials and methods: This split-mouth clinical trial compared the implant...
متن کاملFunctional apparent moduli as predictors of oral implant osseointegration dynamics.
At present, limited functional data exists regarding the application and use of biomechanical and imaging technologies for oral implant osseointegration assessment. The objective of this investigation was to determine the functional apparent moduli (FAMs) that could predict the dynamics of oral implant osseointegration. Using an in vivo dental implant osseous healing model, two FAMs, functional...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 32 1 شماره
صفحات -
تاریخ انتشار 2017