Quantitative evaluation of apical extrusion of debris and irrigants using four rotary instrumentation systems: an in vitro study.

نویسندگان

  • S Aspalli Nagaveni
  • K Reddy Balakoti
  • Karan Smita
  • P Ratnakar
  • S V Satish
  • T Aravind
چکیده

CLINICAL SIGNIFICANCE The apical extrusion of infected debris may have the potential to disrupt the balance between microbial aggression and host defense, resulting in incidents of acute inflammation. During preparation, irrigants and debris, such as bacteria, dentin filings and necrotic tissue may be extruded into the periradicular region leading to periapical inflammation and postoperative flare ups. Using an instrumentation technique that minimizes apical extrusion would be beneficial to both the practitioner and patient. The purpose of the study was to evaluate the weight of debris and volume of irrigant extruded apically from extracted teeth in vitro after endodontic instrumentation using four different rotary root canal instrumentation systems. MATERIALS AND METHODS Four groups of each 20 extracted mandibular premolars were instrumented using one of the four systems: ProTaper Universal (Dentsply Maillefer, Ballaigues, Switzerland)), Hero-shaper (MicroMega, Besancon, France), RaCe (FKG Dentaire, La-Chaux-de-Fonds, Switzerland) and K3 (SybronEndo, West Collins, CA). Debris and irrigant extruded from the apical foramen during instrumentation were collected in preweighed test tubes. Volume of irrigant extruded was noted. The containers were stored in incubator at 70° for two days to evaporate the moisture. Weight of dry debris was noted. STATISTICAL ANALYSIS Data was analyzed using Kruskall-Wallis and Mann-Whitney U test at a significance of 0.001. RESULTS The results indicated that all of the instrumentation systems tested caused measurable apical extrusion of debris and irrigants. Higher extrusion was observed with Protaper system which was statistically significant with Hero-Shaper, RaCe and K3 systems. There were no statistical differences between Hero-shaper, K3 and RaCe systems (p < 0.05). CONCLUSION All instrumentation techniques apically extruded debris and irrigant. However, Hero-shaper, K3 and RaCe systems produced less extruded debris and irrigant than the Protaper system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of apically extruded debris between conventional and 2 rotary instrumentation techniques according to the number of applications(An in vitro study)

A comparison of apically extruded debris between conventional and 2 rotary instrumentation techniques according to the number of applications(An in vitro study) Dr. MH. Zarabi* - Dr. H. Djafarzadeh** - Dr. M. Bidar** *- Associate Professor of Endodontics Dept. - Faculty of Dentistry – Mashhad University of Medical Sciences. **- Endodontist. Background and Aim: Various kinds of hand or rotary te...

متن کامل

Comparison of apically extruded debris and instrumentation time using rotary, endodontic handpiece and hand files in primary molar teeth: (In-vitro )

Abstract Background & Aim : This study was aimed to compare the instrumentation time and the amount of debris extruded apically  during root canal preparation using hand files ,Mtwo rotary system and endodontic handpiece  in primary molar teeth. Method & Material : In this experimental study, sixty roots of  primary molars of human teeth were assigned to three groups (for each group, n=20). The...

متن کامل

Comparative analysis of extrusion of debris and irrigants from the apical foramen using hand and rotary systems

Corresponding author: Vaibhav JainReader , Department of Conservative Dentistry and Endodontics, Chhattisgarh Dental College and Research Institute, Chhattisgarh This article may be cited as:Jain V.Comparative analysis of extrusion of debris and irrigants from the apical foramen using hand and rotary systems.Int J Com Health and Med Res 2017;3(2):66-70 Article Received: 11-05-17 Accepted On: 18...

متن کامل

Evaluation of Apical Extrusion of Debris and Irrigant Using Two New Reciprocating and One Continuous Rotation Single File Systems

OBJECTIVE Apical extrusion of debris and irrigants during cleaning and shaping of the root canal is one of the main causes of periapical inflammation and postoperative flare-ups. The purpose of this study was to quantitatively measure the amount of debris and irrigants extruded apically in single rooted canals using two reciprocating and one rotary single file nickel-titanium instrumentation sy...

متن کامل

Evaluation of conventional, protaper hand and protaper rotary instrumentation system for apical extrusion of debris, irrigants and bacteria- An in vitro randomized trial

BACKGROUND Endodontic instrumentation carries the risk of over extrusion of debris and bacteria. The technique used and the type of instrumentation influences this risk. AIM The purpose of this study was to evaluate and compare the K-file, ProTaper hand and ProTaper rotary instrumentation systems for the amount of apically extruded debris, irrigant solution and intracanal bacteria. DESIGN E...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 14 6  شماره 

صفحات  -

تاریخ انتشار 2013