Diamond stabilization of ice multilayers at human body temperature.
نویسندگان
چکیده
Diamond is a promising material for wear-resistant medical coatings. Here we report a remarkable increase in the melting point of ice resting on a diamond (111) surface modified with a submonolayer of Na+. Our molecular dynamics simulations show that the interfacial ice bilayer melts at a temperature 130 K higher than in free ice, and relatively thick ice films (2.6 nm at 298 K and 2.2 nm at 310 K ) are stabilized by dipole interactions with the substrate. This unique physical effect may enable biocompatibility-enhancing ice overcoatings for diamond at human body temperature.
منابع مشابه
Magnetic Properties and Structural Study of Ni-Co/Cu Multilayers Prepared by Electrodeposition Method
Ni-Co/Cu multilayers have been grown by electrodeposition method from a single electrolyte (based on Ni(SO4).6H2O, Co(SO4).7H2O, Cu(SO4) and H3BO3) using galvanostatic control on titanium sublayers. The X-ray diffraction (XRD) patterns confirmed the multilayered structure with the nanometer thicknesses. Also, electron diffraction x-ray (EDX) analysis confirmed the purity of deposited samples. ...
متن کاملPreparation and Characterization of Superhard Materials of Crystalline Carbon Nitride
13. ABSTRACT (Maximum 200 words) Prompted by the prediction of Cohen and coworkers that beta carbon nitride may have properties similar to diamond, there have been many attempts to synthesize this hypothetical metastable material. We successfully synthesized this material via epitaxial stabilization using TiN(lll) and ZrN(lll) as the growth template. The coatings were CN/TiN or CN/ZrN multilaye...
متن کاملTemperature fluctuations underneath the ice in Diamond Lake, Hennepin County, Minnesota
[1] Diamond Lake in Minnesota is covered every winter with ice and snow providing a modified thermal insulation between water and air. Autonomous temperature sensors, data loggers, were placed in this lake so that hourly measurements could be obtained from the snow-covered ice and water. The sensors that became frozen measured damped and delayed thermal response from the air-temperature fluctua...
متن کاملThe Effects of Acetaminophen on Human Serum Albumin (HSA)
Thermal conformational changes in human serum albumin (HSA) in present with a 10 mM phosphate buffer, at pH=7 have been investigated via circular dichroism (CD) and UV spectroscopic methods. The results indicate that temperature in a range of 25oC to 55oC could induce a reversible conformational change in the structure of HSA. The HSA phase transition corresponds to the physiological and patho...
متن کاملThe Effects of Acetaminophen on Human Serum Albumin (HSA)
Thermal conformational changes in human serum albumin (HSA) in present with a 10 mM phosphate buffer, at pH=7 have been investigated via circular dichroism (CD) and UV spectroscopic methods. The results indicate that temperature in a range of 25oC to 55oC could induce a reversible conformational change in the structure of HSA. The HSA phase transition corresponds to the physiological and patho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Physical review. E, Statistical, nonlinear, and soft matter physics
دوره 76 2 Pt 1 شماره
صفحات -
تاریخ انتشار 2007