Comparison of the Airtraq to the Bonfils Fibroscope for Endotracheal Intubation in a Simulated Difficult Airway
نویسنده
چکیده
Background: Difficult intubation, represent a challenge to anesthetist especially that many cases are encountered after induction of anesthesia. The Airtraq and the Bonfils fibroscopes are new devices designed to facilitate intubation under normal and difficult circumstances. In the present study, the efficacy and the intubation success rate of the Airtraq to the Bonfils fiberscope were evaluated in patients wearing a rigid cervical collar to simulate difficult airway. Methods: Sixty patients ASA I and II requiring intubation as part of anesthesia were enrolled in the study. Patients were randomly assigned according to the device used during intubation to the Airtraq group (n=30) or the Bonfils group (n=30). After administration of IV anesthetics and before intubation, the neck was stabilized with rigid neck collar. Overall intubation success rate, time required for intubation, the number of attempts required for successful intubation, visual analogue scale (VAS, 0-10) for easiness of use of both devices and airway complications related to intubation were recorded. Postoperative sore throat and hoarsness were also evaluated using numerical scale (0-10). Results: The overall success of intubation was 93.3% for the Airtraq and 90% for the Bonfils, p>0.05. Time to successful intubation was significantly shorter for the Airtraq 40 ±8 seconds compared to the Bonfils group 48 ± 10 seconds, p<0.05. The number of required intubation attempts, were comparable between the two groups. One attempt was required in 20 patients (66.6%) versus 19 patients (63.3%) and two attempts were required in 7 patients (23.3%) versus 6 patients (20%) while three attempts were required in 1 patient (3.3%) versus 2 patients (6.6%) in Airtaq group and Bonfils group respectively, p>0.05. The incidence of intubation complication was comparable between the groups. Visual analogue scale for easiness of use of both devices and numerical scale for postoperative sore throat and hoa rsness were comparable between the two groups. Conclusion: Both the Airtraq and the Bonfils fiberscope offer high success rate in patients with predicted difficult airway.
منابع مشابه
Brief report: tracheal intubation using the Bonfils intubation fibrescope or direct laryngoscopy for patients with a simulated difficult airway.
BACKGROUND The Bonfils intubation fibrescope (BIF), a rigid, straight and reusable fibreoptic device, is being used increasingly to facilitate endotracheal intubation after direct laryngoscopy has failed. We tested the hypothesis that, with the BIF compared to direct laryngoscopy, the rate of failed endotracheal intubation could be reduced in patients with a difficult airway, simulated by means...
متن کاملRigid fibrescope Bonfils: use in simulated difficult airway by novices
BACKGROUND The Bonfils intubation fibrescope is a promising alternative device for securing the airway. We examined the success rate of intubation and the ease of use in standardized simulated difficult airway scenarios by physicians. We compared the Bonfils to a classical laryngoscope with Macintosh blade. METHODS 30 physicians untrained in the use of rigid fibrescopes but experienced in air...
متن کاملSubdural or subarachnoid catheter?
been two manikin studies that have described its performance. The device was evaluated in normal and simulated difficult airways. Until now, there have been no descriptions of its use in live subjects. We describe two patients in whom the Airtraq, compared with the Macintosh blade, provided superior views of the larynx facilitating endotracheal intubation. The first case was an anxious 59-yr-ol...
متن کاملA systematic review of the role of videolaryngoscopy in successful orotracheal intubation
UNLABELLED BACKGROUND The purpose of our study was to organize the literature regarding the efficacy of modern videolaryngoscopes in oral endotracheal intubation, then perform a quality assessment according to recommended external criteria and make recommendations for use. METHODS Inclusion criteria included devices with recent studies of human subjects. A total of 980 articles were return...
متن کاملComparison of the Macintosh and Airtraq Laryngoscopes in Endotracheal Intubation Success.
OBJECTIVE Endotracheal intubation of patients is an effective method for controlling airway and breathing. However, laryngoscopy and endotracheal intubation is not easy in every case. There is a recent abundance of equipment used for controlling ventilation and intubation. Airtraq is one of those equipments. In this study, our main objective is to compare the success rates of the Airtraq and Ma...
متن کامل