Dual-energy CT in colorectal cancers: beyond the density measurements.

نویسنده

  • Sivasubramanian Srinivasan
چکیده

I read with interest the article by Özdeniz et al. (1), on dual-source dual-energy computed tomography (DECT) to differentiate fecal matter from neoplasm. The study was well done and was based on density measurements in iodine maps and virtual unenhanced images. I would like to add a few points to the discussion. The main advantage of DECT is material decomposition and the relative iodine concentration can be measured in the iodine map images (2, 3). This is more objective compared with the visual analysis. In true mass lesions, because of iodine uptake, the relative iodine quantification (using region of interest) shows positive value (> 1 mg/ mL). In our example (Fig.), patient had a tumor in the descending colon, which showed increased iodine concentration (>1 mg/mL). However, fecal matter or bowel contents do not show increased iodine concentration. One of the limitations in this study was the small field of view (FOV), as the study was done using first generation dual-source DECT scanner. In second-generation (SOMATOM Definition Flash, Siemens Healthcare) and third-generation (SOMATOM Force, Siemens Healthcare) scanners (4), the FOV is 33 cm (Fig. c) and 35.6 cm, respectively (4). The third-generation scanner is sufficient for most small-sized patients. The limitation of FOV is not present in single-source DECT scanners. A summary of comparison between different DECT scanners is provided in the Table.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Bone Mineral Density Measured by Dual X-ray, Axial Dual-energy Photon X-ray Absorptiometry and Laser Absorptiometry of Calcaneus

The objective of this study was to validate the use of bone mineral measurements of the calcaneus bone by dual X-ray and laser (DXL) in a cross-sectional study carried out in an osteoporosis clinic. Measurements of bone mineral density (BMD) at proximal femur and spine were obtained by dual-energy photon X-ray absorptiometry (DEXA). Osteoporosis was defined by a DEXA T-score <-2.5 at the femora...

متن کامل

Dual-energy CT characteristics of colon and rectal cancer allows differentiation from stool by dual-source CT.

PURPOSE We aimed to determine dual-energy computed tomography (DECT) characteristics of colorectal cancer and investigate effectiveness of DECT method in differentiating tumor from stool in patients with colorectal cancer. METHODS Fifty consecutive patients with colorectal tumors were enrolled. Staging was performed by DECT (80-140 kV) using dual-source CT after rectal air insufflation and wi...

متن کامل

A novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study

  In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...

متن کامل

Assessment of bone mineral density with dual energy X-ray absorptiometry in pre- and post-menopausal women

Background: Osteoporosis is a chronic disease that contributes substantially to decrease physical activity and decline in the quality of life. Osteoporosis can be diagnosed easily with the use of dual-energy X-ray absorptiometry (DXA) equipment. The aim of this study was to investigate the magnitude of bone loss on proximal femur and lumbar spine LS in pre- and post-menopausal women f...

متن کامل

Fabrication of anthropomorphic phantoms for use in total body photon irradiation and total skin electron irradiation studies

Introduction: Total Skin Electron Therapy (TSET) and Total Body Irradiation (TBI) are kinds of treatment which use electron and photon beams to treat special types of cancers. The aim of these techniques are to deliver uniform dose to the entire skin while minimizing delivered dose to organs at risk. To check the homogeneity of dose delivery in TBI and TSET, using a humanoid ph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diagnostic and interventional radiology

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 2017