Contact lens tonometry--application in humans.

نویسندگان

  • B Entenmann
  • Y C Robert
  • P Pirani
  • H Kanngiesser
  • P W Dekker
چکیده

PURPOSE To establish a standard clinical procedure for measuring intraocular pressure (Po) with the contact lens tonometer (CLT), to demonstrate possibilities for analyzing ocular pulsation and performing ophthalmodynamometry. METHODS A reliable histogram-based analyzing system for determining Po is used. First, the ocular pressure was registered with the CLT method and compared with the Goldmann applanation pressure, measured immediately beforehand. Second, ocular pulsation was studied by recording Po for 30 to 70 seconds, and the pulse amplitude was then analyzed. Third, an ophthalmodynamometry method during slit-lamp examination was tested. The central retinal artery was observed through the contact lens while the appositional force was elevated. A mark was set at the systolic and diastolic pressure while observing arterial pulsation (similar to the Korotkoff sounds). RESULTS Compared with the Goldmann method measurements, Po obtained with the CLT method yielded a linear regression of r = 0.7 (right eye) and r = 0.68 (left eye), and was therefore highly significant (P < 0.0001, two-tailed). Analysis of the pulse amplitude showed great variability (range, 1 to 9 mm Hg; means, 2.9 mm Hg [right eye] and 3.0 mm Hg [left eye]). The dependence of the pulse amplitude on Po and age was shown with a correlation coefficient of r = 0.55 and r = 0.59, respectively. The difference between the right and left eye of the person was < 0.5 mm Hg. CONCLUSION The CLT can be used during slit-lamp examination and permits tonometry during ophthalmoscopy, ocular pulsation assessment at different intraocular pressures, and ophthalmodynamometry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The measurement of intraocular pressure over positive soft contact lenses by rebound tonometry

PURPOSE To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. METHODS The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects' right eyes in random order using a Rebound Tonometer (ICare...

متن کامل

Dynamic contour tonometry over silicone hydrogel contact lens.

PURPOSE This study compared the measurements of intraocular pressure (IOP) and ocular pulse amplitude (OPA) using the Dynamic Contour Tonometry (DCT) over silicone hydrogel contact lenses of different modulus. Corneal biomechanics were also measured using the Ocular Response Analyzer (ORA). METHODS Forty-seven young (mean age 22.3 years, standard deviation 1.2 years) subjects had IOP, OPA, co...

متن کامل

Impact of chamber pressure and material properties on the deformation response of corneal models measured by dynamic ultra-high-speed Scheimpflug imaging.

PURPOSE To study the deformation response of three distinct contact lenses with known structures, which served as corneal models, under different chamber pressures using ultra-high-speed (UHS) Scheimpflug imaging. METHODS Three hydrophilic contact lenses were mounted on a sealed water chamber with precisely adjustable pressure: TAN-G5X (41% hydroxyethylmethacrylate/glycolmethacrylate, 550 µm ...

متن کامل

Correction: Ocular Surface Displacement with and without Contact Lenses during Non-Contact Tonometry

PURPOSE To evaluate the displacement of the central ocular surface during non-contact tonometry with and without soft contact lenses and determine the factors associated with the displacement of the central ocular surface and intraocular pressure (IOP) reading changes caused by wearing soft contact lenses (CLs). METHODS One eye each in 21 subjects was studied. The cornea was photographed usin...

متن کامل

Intraocular pressure measurement over soft contact lens by rebound tonometer: a comparative study.

AIM To evaluate the intraocular pressure (IOP) measurements by Icare rebound tonometer over a contact lens in comparison with Goldmann applanation tonometry (GAT). METHODS Fifty patients using contact lens were included in this study. One of the eyes of the patients was selected randomly and their IOP were measured by rebound tonometer with and without contact lens (RTCL, RT respectively) and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 38 12  شماره 

صفحات  -

تاریخ انتشار 1997