Evaluation of the Bio-Rad BioPlex 2200 syphilis multiplex flow immunoassay for the detection of IgM- and IgG-class antitreponemal antibodies.
نویسندگان
چکیده
The laboratory diagnosis of syphilis is based primarily upon serologic findings. Historically, serologic testing for syphilis has relied on assays such as rapid plasma reagin, fluorescent treponemal antibody absorption, Treponema pallidum particle agglutination (TP-PA), and more recently, enzyme immunoassay (EIA). In this study, we evaluated the performance of a novel multiplex flow immunoassay (BioPlex 2200 Syphilis; Bio-Rad Laboratories, Hercules, CA) for the detection of antitreponemal IgG- and IgM-class antibodies. Serum specimens (n = 1,008) submitted for routine treponema-specific antibody testing by syphilis IgM and IgG EIA (Trep-Chek; Phoenix-Biotech, Mississauga, Ontario, Canada) were also analyzed by the BioPlex Syphilis multiplex assay. Specimens showing discordant results were repeat tested, with further discrepancies being arbitrated by TP-PA. Compared directly to the results of EIA, the BioPlex IgG assay demonstrated 98.7% (77/78) sensitivity and 99.4% (916/930) specificity. Compared to the Trep-Chek IgM EIA, the BioPlex IgM assay showed 80% (4/5) sensitivity and 97.9% (652/666) specificity. These results indicate that the BioPlex Syphilis multiplex assay shows similar serological agreement with EIA while allowing for a fully automated random-access platform that provides faster (1.7 h for 100 samples versus 4.5 h by EIA) and higher-throughput (800 samples per 9 h versus 200 samples by EIA) analysis of the syphilis serologic response.
منابع مشابه
Performance of the BioPlex 2200 flow immunoassay in critical cases of serodiagnosis of toxoplasmosis.
The BioPlex 2200 automated analyzer (Bio-Rad Laboratories, Hercules, CA) is a recently developed multiplex analyzer that enables the detection of anti-Toxoplasma, -rubella, and -cytomegalovirus antibodies in the same assay. The aim of this study was to compare this new technology (using the BioPlex 2200 ToRC IgG/IgM kit) in critical cases of serodiagnosis of toxoplasmosis (acute, chronic, or co...
متن کاملHighlights on Novel Technologies for the Detection of Antibodies to Ro60, Ro52, and SS-B
OBJECTIVE We aimed to compare a chemiluminescent immunoassay (CIA, QUANTA Flash) on BIO-FLASH with a multiplex flow immunoassay (MFI) on BioPlex 2200 for the detection of antibodies to Ro60, Ro52, and SS-B. METHODS The study included 241 samples, from patients suffering from systemic autoimmune diseases (n = 108) as well as disease controls (n = 133). All samples were tested for anti-Ro52, an...
متن کاملDetection of immunoglobulin M antibodies specific for Toxoplasma gondii with increased selectivity for recently acquired infections.
Toxoplasma gondii infections can cause serious complications in pregnant women, leading to miscarriage, stillbirth, and birth defects. Definitive diagnosis of T. gondii acute infection is therefore critical for the clinical management of a mother and her fetus. Positive immunoglobulin M (IgM) results are not sufficient as evidence of recent infection, as these antibodies are often present for m...
متن کاملIntrathecal antitreponemal antibody synthesis determination using the INNO-LIA Syphilis Score.
BACKGROUND Laboratory detection of intrathecal synthesis of specific antitreponemal antibodies remains a challenge. Traditional syphilis serology is unable to provide a satisfactory result; therefore, several other diagnostic procedures were used to demonstrate central nervous system (CNS) involvement in this disease. The introduction of molecular methods makes today's laboratory testing easier...
متن کاملIgM class antitreponemal antibody in treated and untreated syphilis.
It is a particular advantage of the indirect fluorescent antibody (IFA) method that antibodies of different immunoglobulin classes may be separately detected and measured by the use of monospecific antiglobulin conjugates. Matuhasi, Mizuoka, and Usui (1966), Kiraly, Bachhausz, Jobbagy, Lajos, and Kovats (1968), Julian, Logan, and Norins (1969), and Atwood and Miller (1969) studied antibodies in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical and vaccine immunology : CVI
دوره 17 6 شماره
صفحات -
تاریخ انتشار 2010