Evaluation of a new transcutaneous bilirubinometer.

نویسندگان

  • M Jeffrey Maisels
  • Enrique M Ostrea
  • Suzanne Touch
  • Sarah E Clune
  • Eugene Cepeda
  • Elizabeth Kring
  • Karin Gracey
  • Cheryl Jackson
  • Deborah Talbot
  • Raywin Huang
چکیده

OBJECTIVE The objective of this study was to evaluate the Minolta/Hill-Rom Air-Shields Transcutaneous Jaundice Meter model JM-103. METHODS We studied a convenience sample of 849 newborns > or =35 weeks of gestation in 3 hospitals. These infants had total serum bilirubin (TSB) levels measured on clinical indication, and transcutaneous bilirubin (TcB) levels were obtained within 1 hour of the TSB levels. The population was 59.2% white, 29.8% black, 4.5% East Asian, 3.8% Middle Eastern, 1.6% Indian/Pakistani, and 1.1% Hispanic. RESULTS There was a close correlation between TSB and TcB values in all of the population groups: white (n = 503, r =.949); black (n = 253, r =.822); and East Asian, Indian/Pakistani, and Hispanic (n = 93, r =.926). In the black population, the correlation was less close than in the other groups, and differences between the TcB and TSB measurements tended to increase with rising TSB values. JM-103 values differed from TSB values by 3 mg/dL or more in 2% of white, 3.2% of other, and 17.4% of black infants. In these black infants, the JM-103 value was always greater than the TSB value. CONCLUSIONS We conclude that TcB measurements using the JM-103 jaundice meter correlate very closely with TSB levels over the range of TSB encountered in this study. Because only 3.3% of our infants had TSB values >15 mg/dL (257 micro mol/L), more data are needed in this range of TSB concentration. The correlation in black infants is not as close as in other groups, but because the tendency in blacks is for the JM-103 to overestimate serum bilirubin levels, dangerous clinical errors are unlikely to occur. The measurement technique is rapid and simple, and it is easy to perform repeated measurements over time, thus reducing the likelihood of error. TcB measurements with the JM-103 jaundice meter should obviate the need for most serum bilirubin levels in newborn infants > or =35 weeks of gestation, although serum bilirubin measurements are still required when treatment with phototherapy or exchange transfusion is being considered.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcutaneous bilirubinometry: an evaluation.

The transcutaneous bilirubinometer was evaluated in 60 term and 10 preterm infants. A significant correlation was found between the transcutaneous index and the total serum bilirubin concentration for both term and preterm infants. The reliability of the transcutaneous bilirubinometer as a screening method was confirmed, and index criteria for serum bilirubin analysis have been suggested for te...

متن کامل

مقایسه میانگین بیلی روبین اندازه گیری شده از طریق بیلی روبینومتر با میانگین بیلی روبین سرم در نوزادان زرد

Introduction: Hyperbilirubinemia is a common benign problem in neonates. Nonetheless, if untreated, severe hyperbilirubinemia is potentially neurotoxic. The standard method for diagnosis of hyperbilirubinemia is determination of serum bilirubin levels in the laboratory that requires a blood sample which is both painful and stressful for neonates and entails cost and time. The objective of thi...

متن کامل

Accuracy of transcutaneous bilirubinometer estimates using BiliCheck in Thai neonates.

BACKGROUND Neonatal jaundice is the most frequently encountered diagnostic and therapeutic problem in the newborn. In the jaundiced infant, it is thought that the binding capacity of plasma albumin is exceeded, which allows free bilirubin to diffuse into and accumulate within extravascular tissues, such as the central nervous system. Affected newborns may develop kernicterus. The standard metho...

متن کامل

Evaluation of a point-of-care transcutaneous bilirubinometer in Chinese neonates at an accident and emergency department.

OBJECTIVE To evaluate the use of a point-of-care transcutaneous bilirubinometer, JM-103 Minolta, for estimation of the serum bilirubin level in the management of neonatal jaundice in term or near-term Chinese neonates. DESIGN Prospective correlation study. SETTING Accident and Emergency Department of a regional hospital in Hong Kong. PATIENTS All term or near-term Chinese neonates aged 3 ...

متن کامل

Transcutaneous bilirubinometer in assessment of neonatal jaundice in northern India.

This study was undertaken from April 2002 to March 2003 to find out the correlation of transcutaneous bilirubinometer index with serum bilirubin levels in term, pre-term, small for gestation age babies, with and without phototherapy in neonates with jaundice. Another aim was to evaluate the transcutaneous bilirubinometer as a screening device for neonatal hyperbilirubinemia by finding the actio...

متن کامل

Evaluation of the Bilichek transcutaneous bilirubinometer in the Chinese new-borns

Objective: To evaluate the relation between transcutaneous bilirubin (TcB) by BiliChek and total serum bilirubin (TSB) in the Chinese neonates compared with another transcutaneous Bilirubinometer (VanHou). Methods: TcB measurements were performed on the forehead by Bilichek and VanHou. Total serum bilirubin (TSB) was determined within 5 minutes after TcB measurement. The correlation and agreeme...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pediatrics

دوره 113 6  شماره 

صفحات  -

تاریخ انتشار 2004