Severe hemolysis with a fabric-worn cloth-covered aortic valve prosthesis.
نویسندگان
چکیده
A patient developed severe hemolytic anemia one year after insertion of a cloth-covered aortic valve prosthesis (Starr-Edwards No. 2320). The cloth over the three struts was disrupted but showed coverage with mostly organized collagen. Hemolysis stopped after replacement with a porcine heterograft. Fabric wear seems to augment the hemolysis in patients with cloth-covered artificial valves.
منابع مشابه
Valve dysfunction of the cloth-covered Starr-Edwards ball valve.
BACKGROUND Between June 1968 and March 1977, Starr-Edwards cloth-covered ball valves were used for valve replacement on a routine basis. METHODS AND RESULTS Among the 66 operative survivors who underwent an isolated aortic or mitral valve replacement, 20 patients required reoperation 22 times because of valve dysfunction, thromboembolic complication, paravalvular leakage, hemolytic anemia, an...
متن کاملThe pathology of wear in the Beall model 104 heart valve prosthesis.
We examined 13 Beall model 104 prostheses recovered at surgery or autopsy 10 to 84 1/2 months after insertion and observed the pattern of prosthesis wear. We defined wear as "mild" when the disc was notched but neither the metal of the struts was exposed not the cloth seat torn. In "moderate" wear the disc was notched, the Teflon coating of the struts was worn away exposing the underlying meta...
متن کاملHemolysis in patients with the cloth-covered aortic valve prosthesis. Changing severity of hemolysis and prediction of anemia.
From the Departments of Medicine, Pathology and Surgery of the University of Michigan Medical Center, Ann Arbor, Mich. Manuscript accepted April 3, 1974. Address for reprints: John T. Santinga, MD, Department of Medicine, The University of Michigan Medical Center, Ann Arbor, Mich. 48104. This paper is addressed to two questions: (1) Is there evidence for Increasing hemolysis in patients with a ...
متن کاملThrombo-embolic complications of the cloth-covered Starr-Edwards prostheses No. 2300 aortic and No. 6300 mitral.
The thrombo-embolic complications of the cloth-covered Starr-Edwards prostheses No. 2300 aortic and No. 6300 mitral followed for an average of 14 months in 155 patients are reviewed. There was a high incidence of early fatal and disabling thrombo-embolus in patients 'having mitral valve replacement. Late emboli were more common after aortic valve replacement. Anticoagulant control was unsatisfa...
متن کاملAortic Valve replacement with Reduction Aortoplasty with Mesh Prosthesis in 75 years old with Sever aortic Regurgitation with Aortic Aneurysm
Although classic and standard procedure for patients with ascending Aorta aneurysm with Sever aortic Regurgitation is Bentall surgery but in some selected cases this complex surgery was not performed with different reason like advanced age and coexisting comorbidity involving renal and hepatic and lung Function. In our cases 75 years old man with chronic renal failure ( Cr= 3.2 ) who was known ...