Handheld echocardiographic screening for rheumatic heart disease by non-experts.

نویسندگان

  • Michelle Ploutz
  • Jimmy C Lu
  • Janet Scheel
  • Catherine Webb
  • Greg J Ensing
  • Twalib Aliku
  • Peter Lwabi
  • Craig Sable
  • Andrea Beaton
چکیده

OBJECTIVES Handheld echocardiography (HAND) has good sensitivity and specificity for rheumatic heart disease (RHD) when performed by cardiologists. However, physician shortages in RHD-endemic areas demand less-skilled users to make RHD screening practical. We examine nurse performance and interpretation of HAND using a simplified approach for RHD screening. METHODS Two nurses received training on HAND and a simplified screening approach. Consented students at two schools in Uganda were eligible for participation. A simplified approach (HAND performed and interpreted by a non-expert) was compared with the reference standard (standard portable echocardiography, performed and interpreted by experts according to the 2012 World Heart Federation guidelines). Reasons for false-positive and false-negative HAND studies were identified. RESULTS A total of 1002 children were consented, with 956 (11.1 years, 41.8% male) having complete data for review. Diagnoses included: 913 (95.5%) children were classified normal, 32 (3.3%) borderline RHD and 11 (1.2%) definite RHD. The simplified approach had a sensitivity of 74.4% (58.8% to 86.5%) and a specificity of 78.8% (76.0% to 81.4%) for any RHD (borderline and definite). Sensitivity improved to 90.9% (58.7% to 98.5%) for definite RHD. Identification and measurement of erroneous colour jets was the most common reason for false-positive studies (n=164/194), while missed mitral regurgitation and shorter regurgitant jet lengths with HAND were the most common reasons for false-negative studies (n=10/11). CONCLUSIONS Non-expert-led HAND screening programmes offer a potential solution to financial and workforce barriers that limit widespread RHD screening. Nurses trained on HAND using a simplified approach had reasonable sensitivity and specificity for RHD screening. Information on reasons for false-negative and false-positive screening studies should be used to inform future training protocols, which could lead to improved screening performance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevalence of rheumatic heart disease detected by echocardiographic screening.

BACKGROUND Epidemiologic studies of the prevalence of rheumatic heart disease have used clinical screening with echocardiographic confirmation of suspected cases. We hypothesized that echocardiographic screening of all surveyed children would show a significantly higher prevalence of rheumatic heart disease. METHODS Randomly selected schoolchildren from 6 through 17 years of age in Cambodia a...

متن کامل

A rapid echocardiographic screening protocol for rheumatic heart disease in Samoa: a high prevalence of advanced disease.

BACKGROUND Echocardiography has been proposed as a method to screen children for rheumatic heart disease. The World Heart Federation has established guidelines for echocardiographic screening. In this study, we describe a rapid echocardiogram screening protocol according to the World Heart Federation guidelines in Samoa, endemic for rheumatic heart disease. METHODS We performed echocardiogram...

متن کامل

Echocardiographic Screening for Rheumatic Heart Disease in Indigenous Australian Children: A Cost–Utility Analysis

BACKGROUND Rheumatic heart disease (RHD) remains a leading cause of cardiovascular morbidity and mortality in children and young adults in disadvantaged populations. The emergence of echocardiographic screening provides the opportunity for early disease detection and intervention. Using our own multistate model of RHD progression derived from Australian RHD register data, we performed a cost-ut...

متن کامل

Screening for rheumatic heart disease: is a paradigm shift required?

This focused review presents a critical appraisal of the World Heart Federation criteria for the echocardiographic diagnosis of rheumatic heart disease (RHD) and its performance in African RHD screening programmes. It identifies various logistical and methodological problems that negatively influence the current guideline's performance. The authors explore novel RHD screening methodology that c...

متن کامل

Clinical Impact and Costs of Echocardiographic Screening for Rheumatic Heart Disease

A n 18-year-old lies in bed in a lower-income country. He has just experienced an embolic stroke that originated on his infected mechanical mitral prosthesis, placed 2 years prior for severe rheumatic mitral stenosis. This true story is paradigmatic of the burdens created by rheumatic heart disease (RHD) in developing nations and underserved regions of developed nations. What if this tragedy co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 102 1  شماره 

صفحات  -

تاریخ انتشار 2016