Comparing measured total carbon dioxide and calculated bicarbonate.

نویسندگان

  • Nadzimah Mohd Nasir
  • Pavai Sthaneshwar
  • Putri Junaidah Megat Yunus
  • Sook-Fan Yap
چکیده

INTRODUCTION The objective of the study is to determine the level of agreement between measured total carbon dioxide (TCO2) and calculated bicarbonate (HCO3-) in our laboratory. MATERIALS AND METHODS TCO2 and HCO3- values of 1820 samples drawn at the same time from the patient were compared. TCO2 from venous samples was measured on Dimension RxL while HCO3- was obtained from arterial blood gas samples analyzed on Radiometer ABL 700. RESULTS The TCO2 and HCO3- values correlated well (r = 0.977, p < 0.001), with the correlation given by the equation, y = 0.986x - 0.5335. Using Bland-Altman analysis, the bias was 0.87 mmol/L (SD 1.42 mmol/L), and the limits of agreement (LOA) were -1.92 to 3.67 mmol/L. Story and Poustie's criteria were applied to study the agreement between these two methods. Based on the first criterion that the bias between TCO2 and HCO3- should be less than +/- 1 mmol/L, the results for the two methods appear to be in good agreement. The second criterion requires that the LOA between the two methods should range between a bias of +/- 2 mmol/L or a total span of 4 mmol/L; the LOA was exceeded in our study. Using the total allowable error in the Bland Altman plot also showed that the two values cannot be used interchangeably especially at the lower values. CONCLUSIONS TCO2 did not show good agreement with HCO3-. Clinicians should be aware of this discrepancy and hence should be cautious when using HCO3- for management of acid-base disorders.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Discrepancy between Measured Serum Total Carbon Dioxide Content and Bicarbonate Concentration Calculated from Arterial Blood Gases

Large differences between the concentrations of serum total carbon dioxide (TCO2) and blood gas bicarbonate (HCO3 (-)) were observed in two consecutive simultaneously drawn sets of samples of serum and arterial blood gases in a patient who presented with severe carbon dioxide retention and profound acidemia. These differences could not be explained by the effect of the high partial pressure of ...

متن کامل

Determination of plasma bicarbonate of neonates in intensive care.

Most modern blood-gas analyzers are programmed to use the Henderson-Hasselbalch equation to calculate a value for plasma bicarbonate. It has been suggested, however, that among acutely ill patients, including newborns, these calculated values may be at variance with measured total CO2. To assess the clinical significance of such errors, we compared calculated bicarbonate with measured total CO2...

متن کامل

Experimental Investigation and Modeling of Carbon Dioxide Adsorption from Model Flue gas

In this work, the adsorption of carbon dioxide from model flue gas on different adsorbents has been investigated. Using simplified modeling, parameters such as the total mass transfer coefficient and the effective diffusivity have been determined. Experiments were carried out in two sections: firstly, adsorption of pure carbon dioxide on different adsorbents was measured at pressures ranging fr...

متن کامل

A semi-empirical mathematical model useful for describing the relationship between carbon dioxide, pH, lactate and base in a bicarbonate-buffered cell-culture process.

The purpose of the present study was to develop a quantitative relationship between the primary factors of state affecting pH control in a bicarbonate-buffered medium. Starting with the Henderson-Hasselbach equation, several assumptions led to the following equation: L = B(T)-s x dCO2 x 10(pH-pK) where L is the lactate concentration (mM), B(T) is the total amount of base added (mM), s is the so...

متن کامل

Direct potentiometric determination of sodium ion in blood. III. Influence of (bi)carbonate.

We measured the emf of a sodium ion-selective electrode in NaCl-NaHCO3 solutions (160 mmol of Na+, 160-120 mmol of Cl-, and 0-40 mmol HCO3- per liter) with a home-built cell in steady-state after 10 min and with two commercial direct potentiometric analyzers about 20 s after the sample was introduced. Substitution of HCO3- for Cl- resulted in a small decrease in emf. We calculated the effect of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Malaysian journal of pathology

دوره 32 1  شماره 

صفحات  -

تاریخ انتشار 2010