Streamlining EPID-based IMRT quality assurance: auto-analysis and auto-report generation

نویسندگان

  • Aitang XING
  • Sankar ARUMUGAM
  • Shrikant DESHPANDE
  • Lois HOLLOWAY
  • Gary GOOZEE
  • Alison GRAY
چکیده

Using an EPID for patient specific IMRT QA is an efficient way to verify patient plans prior to the treatment. Our centres’ current EPID dosimetry method is based on a water equivalent depth approach, where EPID images of each IMRT field are converted to dose images and compared to Treatment planning system calculated dose images using a commercial software tool. Two physicists across two sites perform the analysis for an average of 12 new IMRT patients per week. To speed up this process, an in-house program called AutoEPIDIMRTQA was developed. The program automatically performs the following tasks sequentially: reading and converting raw EPID images acquired on either a Siemens Oncor or Elekta Synergy linear accelerator, registering them with planar dose images calculated by Pinnacle (Philips) or CMS XiO (Elekta) treatment planning systems, analyzing the profiles for registered images and calculating the Gamma map. Finally an IMRT QA report is automatically generated. AutoEPIDIMRTQA was validated against commercial software. The analysis time for a typical 9-beam IMRT head-neck patient decreases from 30 minutes to 4 minutes. The total QA time was reduced by 40% using AutoEPIDIMRTQA. Thus we have demonstrated a significant reduction in the time burden for physics staff performing IMRT QA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Study on Instrumental Precision of Refrigerated and Non-Refrigerated Auto-Analyzers in Order to Improve Quality Assurance in Biochemistry Laboratory

Background and Objective: Quality control is one of the most important components in order to improve quality assurance in laboratories during analytical steps. For this purpose, coefficient of variation plays an important role. Due to the fast improvement in technology, application of inferential statistics for the comparisons ...

متن کامل

Performance Evaluation of the Siemens Electronic Portal Imaging Device for IMRT Plan Verification

A commercially available amorphous Silicon Electronic Portal imaging device (aSi-EPID) installed onto Siemens Oncor Linear accelerator was evaluated with the objective to be implemented for IMRT quality assurance. EPID properties were investigated; these include reproducibility, dependences between the relative EPID responses and field size, dose rate were studied for both photon beams. To dete...

متن کامل

WE-G-BRB-02: MU-EPID an EPID Based Tool for IMRT Quality Assurance.

PURPOSE A software program (MU-EPID) has been developed to perform patient specific IMRT pre-treatment QA verification using an electronic portal imaging device. METHODS The software converts measured images of intensity modulated beams delivered to an EPID, into fluence maps that can be imported in the treatment planning system. The dose can then be calculated in the patient anatomy and comp...

متن کامل

3D EPID-based in vivo dosimetry for IMRT and VMAT

In this paper the various approaches of EPID-based in vivo IMRT and VMAT dose verification, and their clinical implementation, are described. It will be shown that EPID-based in vivo dosimetry plays an important role in the total chain of verification procedures in a radiotherapy department. EPID-based dosimetry, in combination with in-room imaging, is a fast and accurate tool for 3D in vivo ve...

متن کامل

Evaluation of a fast method of EPID-based dosimetry for IMRT and Comparison with 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT

Introduction: Electronic portal imaging devices (EPIDs) could potentially be useful for intensity-modulated radiation therapy (IMRT) and VMAT QA. The data density, high resolution, large active area, and efficiency of the MV EPID make it an attractive option. However, EPIDs were designed as imaging devices, not dosimeters, and as a result they do not inherently measure dose in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013