Windowless Open Photoacoustic Helmholtz Cell
نویسنده
چکیده
A phenomenon which is usually considered as the main disadvantage of photoacoustic Helmholtz cells is photoacoustic background signal resulting from the light absorption by the cell windows. Although there are methods which reduce this background signal, e.g. light wavelength modulation or time domain filtering of the photoacoustic response from the sample, the methods are limited to particular applications, and none of them would completely remove the mentioned background signal. The paper presents design of a windowless open photoacoustic Helmholtz cell, and preliminary results of frequency response measurements of such a cell. Removal of the windows eliminated the main source of the photoacoustic background signal. Additionally, the proposed design allows for unrestricted or forced flow of the fluid filling the cell. As a result, the cell can be easily adapted for continuous, real-time photoacoustic measurements. Under proper selection of the cell dimensions, Q-factors of such open photoacoustic Helmholtz resonators are comparable to the Q-factors of corresponding closed Helmholtz cells.
منابع مشابه
Improved Open Photoacoustic Helmholtz Cell
This paper presents the design of an open photoacoustic Helmholtz cell in which high acoustic volumes with quarter-wave ducts act as high-impedance separators between themainHelmholtz cell structure and the exterior. As a result, penetration of the external acoustic noise into the cell was substantially reduced in comparison to earlier open Helmholtz cell designs. Although the presented cell is...
متن کاملSignal-to-Noise Analysis of the Improved Open Photoacoustic Helmholtz Cell
Open photoacoustic cells are often used in continuous-flow photoacoustic measurements. Such cells are sensitive to external noise penetration. The improved open photoacoustic Helmholtz cell has much better external noise attenuation than the previously known designs. This paper describes how mechanical dimensions of such a cell influence its signal-to-noise ratio. The analysis was performed by ...
متن کاملNovel Helmholtz-based photoacoustic sensor for trace gas detection at ppm level using GaInAsSb/GaAlAsSb DFB lasers.
A new and compact photoacoustic sensor for trace gas detection in the 2-2.5 microm atmospheric window is reported. Both the development of antimonide-based DFB lasers with singlemode emission in this spectral range and a novel design of photoacoustic cell adapted to the characteristics of these lasers are discussed. The laser fabrication was made in two steps. The structure was firstly grown by...
متن کاملClosed/Open-Cell Photoacoustic Imaging for Spectroscopic Measurements
Photoacoustic imaging using a closed photoacoustic cell and an open photoacoustic cell with gasmicrophone detection scheme was described. R/G/B LED light sources were used for the closed photoacoustic (PA) cell configuration. The colored specimen enclosed in a PA cell was imaged with R/G/B color light sources, and an image restored from the inverted PA images was compared with the original imag...
متن کاملLoss-improved electroacoustical modeling of small Helmholtz resonators.
Modeling of small Helmholtz resonators based on electroacoustical analogies often results in significant disagreement with measurements, as existing models do not take into account some losses that are observed in practical implementations of such acoustical circuits, e.g., in photoacoustic Helmholtz cells. The paper presents a method which introduces loss corrections to the transmission line m...
متن کامل