Passive control of a biventricular assist device with compliant inflow cannulae.

نویسندگان

  • Shaun David Gregory
  • Mark John Pearcy
  • Daniel Timms
چکیده

Rotary ventricular assist device (VAD) support of the cardiovascular system is susceptible to suction events due to the limited preload sensitivity of these devices. This may be of particular concern with rotary biventricular support (BiVAD) where the native, flow balancing Starling response is diminished in both ventricles. The reliability of sensor and sensorless-based control systems which aim to control VAD flow based on preload has limitations, and, thus, an alternative solution is desired. This study introduces a compliant inflow cannula (CIC) which could improve the preload sensitivity of a rotary VAD by passively altering VAD flow depending on preload. To evaluate the design, both the CIC and a standard rigid inflow cannula were inserted into a mock circulation loop to enable biventricular heart failure support using configurations of atrial and ventricular inflow, and arterial outflow cannulation. A range of left (LVAD) and right VAD (RVAD) rotational speeds were tested as well as step changes in systemic/pulmonary vascular resistance to alter relative preloads, with resulting flow rates recorded. Simulated suction events were observed, particularly at higher VAD speeds, during support with the rigid inflow cannula, while the CIC prevented suction events under all circumstances. The compliant section passively restricted its internal diameter as preload was reduced, which increased the VAD circuit resistance and thus reduced VAD flow. Therefore, a CIC could potentially be used as a passive control system to prevent suction events in rotary left, right, and biventricular support.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tentacles: a novel device for exposing the heart for the insertion of left apical assist device cannulae.

BACKGROUND The implantation of ventricular assist devices is a well-established procedure for the treatment of imminent heart failure. The exact positioning of the left ventricular apical inflow cannula is crucial, because inflow restrictions might occur when the cannula is placed too close to the interventricular septum or a papillary muscle. We report a novel technique using the Tentacles 3-p...

متن کامل

In vivo evaluation of the Nimbus axial flow ventricular assist system. Criteria and methods.

Continuing in vivo trials are being conducted at the University of Pittsburgh using the Nimbus axial flow blood pump (AxiPump). To date, 14 sheep experiments have been performed to address several issues related to short-term support. Six acute experiments (< 6 hr) have been performed to assess hemodynamics related to speed regulation and to determine anatomic placement of the pump and cannulae...

متن کامل

A compliant, banded outflow cannula for decreased afterload sensitivity of rotary right ventricular assist devices.

Biventricular support with dual rotary ventricular assist devices (VADs) has been implemented clinically with restriction of the right VAD (RVAD) outflow cannula to artificially increase afterload and, therefore, operate within recommended design speed ranges. However, the low preload and high afterload sensitivity of these devices increase the susceptibility of suction events. Active control s...

متن کامل

Biventricular circulatory support with two miniaturized implantable assist devices.

BACKGROUND Up to 30% of patients with end-stage heart failure experience biventricular failure that requires biventricular mechanical support. For these patients, only bulky extracorporeal or implantable displacement pumps or the total artificial heart have been available to date, which enables only limited quality of life for the patients. It was our goal to evaluate a method that would allow ...

متن کامل

Cardiac Transplantation and Surgery for Heart Failure Biventricular Circulatory Support With Two Miniaturized Implantable Assist Devices

Background—Up to 30% of patients with end-stage heart failure experience biventricular failure that requires biventricular mechanical support. For these patients, only bulky extracorporeal or implantable displacement pumps or the total artificial heart have been available to date, which enables only limited quality of life for the patients. It was our goal to evaluate a method that would allow ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Artificial organs

دوره 36 8  شماره 

صفحات  -

تاریخ انتشار 2012