Electromagnetic Losses in Magnetic Shields for Buried High Voltage Cables

نویسندگان

  • P. Sergeant
  • S. Koroglu
  • Selim Koroglu
چکیده

The electromagnetic losses and shielding efficiency of shields for a buried three phase high voltage cable are studied for several shielding configurations. The shields are U-shaped gutters covered with plates, and the power cables are positioned either in trefoil or in flat configuration. The shielding efficiency and the losses are compared for shields with the same geometry but several shielding materials: aluminium, and two ferromagnetic steel grades. The numerical models are validated with experimental results. From the experiments, it is observed that the average reducing factor of the flux density is about 7 with the flat cable configuration while the average reducing factor of the flux density is about 5 with the trefoil cable configuration. But the power losses in the DX52 shield for trefoil configuration is about 40% lower compared to the flat configuration. In case of trefoil configuration, the losses are 12.14 W/m per meter length in the shield for a current of 750A. Next to the shield material and the cable configuration, the paper investigates the influence of several parameters on both the shielding efficiency and the losses: the size of the shield, the current amplitude in the cable and the thickness of the shield. Received 22 February 2011, Accepted 6 April 2011, Scheduled 13 April 2011 Corresponding author: Selim Koroglu ([email protected]). † Also with Department of Electrotechnology, Faculty Applied Engineering Sciences, University College Ghent, Ghent B-9000, Belgium. 442 Sergeant and Koroglu

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrical and Thermal Analysis of Single Conductor Power Cable Considering the Lead Sheath Effect Based on Finite Element Method

This paper investigates the effect of metallic sheaths on losses and temperature of medium voltage power cables. Two grounding methods of sheaths, including both ends bonding and single point bonding that causes different situations on cable ampacity, are considered. Electrical losses of cables that are main sources of heat are calculated in both conductor and metallic sheath of the cables. She...

متن کامل

بررسی میزان شدت میدان ‌های الکترومغناطیسی در اطراف منابع  ولتاژ بالا در بخش‌ های بیمارستانی همدان

A MicrosoftInternetExplorer4 Background and Objectives: Biological effects of non-ionizing radiation on the body of living organisms have been studied by researchers in recent years. High Voltage medical equipments are one of the sources generating electromagnetic fields. The electromagnetic field intensity of the medical equ...

متن کامل

Measurement and Analysis of Extremely Low Frequency Electromagnetic Field Exposure in Oman

Concern about the possible health effects from exposure to Extremely Low Frequency (ELF) electromagnetic fields is increasing worldwide. This paper presents analyses of measurements of low frequency magnetic and electric fields caused by conductors carrying current in the Oman electric power system. Measurements were taken during the summer period at around 3 PM to capture peak loads. Field mea...

متن کامل

Using CAE to Design Magnetic Shielding Solutions

Electromagnetic designs are found in a wide variety of industrial and R&D applications: cables, magnetic shielding, transmission lines, high voltage systems, and other EM systems. Engineers need to understand the electromagnetic behaviors (e.g. fields, forces, eddy currents, etc.) of these designs so that costs and performance can be effectively managed. In the past, engineers were limited to c...

متن کامل

Optimal Sitting, Sizing, and Operation of Batteries and Passive Filters to Mitigate Over-voltage and Harmonic Problems in Distribution Networks with High Photovoltaic Penetration

Photovoltaic systems (PVs), despite their many advantages, may have effects such as power quality issues (voltage and harmonics increase), short-circuits level increase, protection issues, and transient stability for network. Some of these effects are due to the high PV penetration, which encounters the network with the over-voltage and harmonics problems. In this paper, the location, size and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011