Evaluation of new technique of sterilization using biological indicator

نویسندگان

  • Nomal Chintan Sheth
  • Yogesh V. Rathod
  • Pratima R. Shenoi
  • Deepa D. Shori
  • Rajiv T. Khode
  • Amruta P. Khadse
چکیده

Background A novel technique of sterilization of endodontic files is introduced in this article. Aims Newly introduced sterilization unit, named "SteriFast" is compared with autoclave and glass bead sterilizer using biological indicator. Materials and Methods Spore strips of Bacillus pumilus were cultured in nutrient broth. This cultured media was used to contaminate the experimental samples of endodontic files. These contaminated files were sterilized using three different techniques. The sterilized files were transferred into nutrient medium under aseptic condition. The results were observed after 24 h, 48 h, and 7 days. Results The results showed that autoclave and new sterilization device (SteriFast) showed complete sterilization. The files sterilized using glass bead sterilizer showed bacterial growth (80%). Conclusions Thus, it proves that autoclave and SteriFast are ideal techniques of sterilization of endodontic files. Glass bead sterilizer does not completely sterilize the files. The article also compares SteriFast and autoclave in other aspects such as its design, basic principle, advantages, and disadvantages. The article also describes features and design of SteriFast, used for all kind of small dental instruments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of chemical and biological consequences of soil sterilization methods

Sterilized soils are commonly used for the study of xenobiotic sorption and as an abiotic control in biodegradation experiments. They are also used for the chemical study of nitrogen and carbon cycle processes and the elimination of the biological factors. In this research the effects of different soil sterilization methods such as autoclaving, fumigating and exposure to ultraviolet and microwa...

متن کامل

An evaluation of the performance of autoclave devices in the sterilization process using biological method in dental Clinics of Birjand in 2019: Short Communication

Today, due to the high prevalence of infectious diseases and the risk of infection transmission in dental clinics, the control of infectious agents is critically important in dentistry. Given the importance of proper autoclave performance in dental processes, the aim of this study was to evaluate the performance of autoclave devices in the sterilization process using biological methods in denta...

متن کامل

Developing the Use of Quality Indicators in Sterilization Practices

BACKGROUND Health-care-associated infections are a major threat to the safety of patient care. Control of such problem is a major criterion for hospital accreditation. This study was aimed to determine the developing use of chemical (class 6 products) and biological indicators in Tabriz district hospitals since 1997 to 2011. METHODS We conducted this time-trend interventional study with all o...

متن کامل

Comparison of a rapid readout biological indicator for steam sterilization with four conventional biological indicators and five chemical indicators.

OBJECTIVE In this study, we compare a new biological indicator that provides results within 3 hours with four conventional, 48-hour biological indicators and five chemical indicators. DESIGN Biological indicators tested included the conventional Attest 1262, Proof Plus, Assert, and Biosign, and the new Attest 1292 Rapid Readout biological indicator. Chemical indicators tested included Comply,...

متن کامل

New disinfection and sterilization methods.

New disinfection methods include a persistent antimicrobial coating that can be applied to inanimate and animate objects (Surfacine), a high-level disinfectant with reduced exposure time (ortho-phthalaldehyde), and an antimicrobial agent that can be applied to animate and inanimate objects (superoxidized water). New sterilization methods include a chemical sterilization process for endoscopes t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2017