Implantation of a leadless cardiac pacemaker for recurrent pocket infections

نویسندگان

  • Philip M. Chang
  • Rahul N. Doshi
چکیده

Infections involving cardiovascular implantable electronic devices (CIEDs) remain an unfortunate indication for repeated device-related procedures, including extractions and reimplantations. Recurrent infections involving transvenous leads and superficial device pockets may eventually lead to epicardial lead implantation and generator placement in deeper tissue planes, both of which require a more invasive surgical approach. We present a unique case of a patient with recurrent CIED-related pocket infections involving both transvenous and epicardial pacing systems that was ultimately addressed with implantation of an investigational leadless cardiac pacemaker.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ECGs and Pacemakers

Leadless pacemakers will most likely be the future of cardiac pacing. Leadless pacing employs a singlechamber system to pace only the right ventricle and is fully self-contained, which eliminates the need for leads. These systems, implanted by using a transcatheter sheath, are indicated for patients who need right ventricular pacing only. These devices enable patients to avoid lead-related comp...

متن کامل

Leadless cardiac pacing

Transvenous cardiac pacemakers definitely improve quality of life and reduce mortality in at-risk patients, but they are associated with several potential device-related complications. Approximately 10% of patients experience complications related to transvenous implantation of the pacemaker. These may be attributable to either the pulse generator (hematoma, skin breakdown, pocket infection) or...

متن کامل

Retrieval of the Leadless Cardiac Pacemaker

Leadless cardiac pacemakers (LPs) have emerged as a safe and effective alternative to conventional transvenous pacemakers for patients with an indication for single-chamber ventricular pacing. In 2 prospective studies with intermediate follow-up, leadless pacemakers exhibited high acute implantation success rates and stable pacing performance at 6 months. Despite these promising results, the ab...

متن کامل

Implantation of the Micra leadless pacemaker in a patient with a low body mass index of 16

A 71-year-old female patient has a history of complete heart block and recurrent pacemaker site infection requiring multiple pacemaker explanations. A leadless pacemaker using passive fixation was inserted into the right ventricular apex via transvenous approach without complications. This case illustrates the feasibility of implanting a leadless pacemaker system in a small-sized adult with a l...

متن کامل

Successful implantation of a Micra leadless pacemaker via collateral femoral vein and inferior vena cava filter

This case details the successful implementation of a leadless pacemaker device in a patient with multiple venous occlusions and an IVC filter. As the incidence of IVC filters increases in patients with dysrhythmias, further investigations are required to determine the risk and safety of leadless pacemaker placement in this population.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -