Reactive energy and power factor L2 1.1 The nature of reactive energy L2 1.2 Equipment and appliances requiring reactive energy L2 1.3 The power factor L3 1.4 Practical values of power factor L4 Why to improve the power factor? L5 2.1 Reduction in the cost of electricity L5 2.2 Technical/economic optimization L5 How to improve the power factor? L7 3.1 Theoretical principles L7 3.2 By using what equipment? L7 3.3 The choice between a fixed or automatically-regulated bank L9 of capacitors Where to install power factor correction capacitors? L 0 4.1 Global compensation L10 4.2 Compensation by sector L10 4.3 Individual compensation L11 How to decide the optimum level of compensation? L 2 5.1 General method L12 5.2 Simplified method L12 5.3 Method based on the avoidance of tariff penalties L14 5.4 Method based on reduction of declared maximum apparent power (kVA) L14 Compensation at the terminals of a transformer L 5 6.1 Compensation to increase the available active power output L15 6.2 Compensation of reactive energy absorbed by the transformer L16 Power factor correction of induction motors L 8 7.1 Connection of a capacitor bank and protection settings L18 7.2 How self-excitation of an induction motor can be avoided L19 Example of an installation before and L20 after power-factor correction
منابع مشابه
Modified Bi-directional AC/DC Power Converter with Power Factor Correction
Most existing power converters and industrial motor drive systems draw non-sinusoidal currents from the supply. Non-sinusoidal currents contained harm harmonics disturb the power supply which it causes serious concern for reliability. Other equipments that use the same power supply are adversely affected. This paper suggests the operation and performance of a new modified AC/DC converter that ...
متن کاملActive Power Filter Design by a Novel Approach of Multi-Objective Optimization
This paper presents an innovative active power filter design method to simultaneously compensate the current harmonics and reactive power of a nonlinear load. The power filter integrates a passive power filter which is a RL low-pass filter placed in series with the load, and an active power filter which comprises an RL in series with an IGBT based voltage source converter. The filter is assumed...
متن کاملImproving the performance of UPQC under unbalanced and distortional load conditions: A new control method
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...
متن کاملAn Improved Control Method Based on Modified Delta-Sigma Modulator for Buck Converter
This paper proposes an improved control method based on modified Delta-Sigma Modulator (DSM) to enhance transient response and improve harmonic contents of buck DC-DC converter. The main advantages of the proposed method are improving the output voltage frequency spectrum, correction of the output voltage harmonic contents and sideband harmonics, reduction of switching noise peaks at the output...
متن کاملHarmonic Mitigation, Power Factor Correction & Energy Saving with Proper Transformer & Phase Shifting Techniques
Harmonics in electrical distribution systems are created from a number of sources and produce a variety of undesirable side effects. It is therefore important to understand all solutions that are available. Phase shifting will be reviewed as one concept for solving certain types of problems related to power quality. Both theoretical concepts and a case study are presented. Index Terms – Harmoni...