Multicomponent Analysis by Flow Injection Using a Partial Least-squares Model. Determination of Copper and Zinc in Serum and Metal Alloys
نویسندگان
چکیده
A partial least-squares multivariate calibration method for the resolution of mixtures of metal ions from the spectra of the complexes produced in a flow injection (FI) system has been developed. The method has been applied to the simultaneous determination of Cull and Znii with 4-(4'-methyl-2'-thiazolylazo)-2-methylresorcinol. The reagent exhibits a high absorbance and its spectrum strongly overlaps with the spectra of the complexes that it forms with copper and zinc ions. Chemical and FI variables influencing the system have been optimized and the proposed method validated on the determination of Cu and Zn in blood serum and metal alloys.
منابع مشابه
Simultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium
Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...
متن کاملSimultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium
Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...
متن کاملFlow-Injection Solid Phase Partial Least-Squares Spectrophotometric Simultaneous Determination of Iron, Nickel and Zinc
Solid phase spectrophotometry (SPS) provides effective methods to combine metal ion preconcentration and their spectrophotometric determination, by integrating the formation of colored complexes and their fixation on the surface of a solid support placed inside the measurement cell. The coupling between flow injection analysis (FIA) and SPS (FI-SPS) makes it unnecessary to reach equilibrium con...
متن کاملSimultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares
A partial least squares (PLS) calibration model was developed for the simultaneous spectrophotometricdetermination of Pb (ΙΙ), Cu (ΙΙ) and Ni (ΙΙ) using xylenol orange as a chromogenic reagent. The parameterscontrolling behavior of the system were investigated and optimum conditions were selected. The calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead...
متن کاملSpectrophotometric simultaneous determination of nickel, cobalt and copper by orthogonal signal correction–partial least squares
A method for the simultaneous spectrophotometric determination of nickel, cobalt and copper based on theformation of their complexes with 2-(2-Thiazolylazo)-p-Cresol (TAC) in micellar media of Triton X-100 isproposed. The absorbance spectra were recorded in the range of 500 to 800 nm. The linear concentrationrange for nickel, cobalt and copper in solution calibration sets were 0.05–1.80, 0.10–6...
متن کامل