Measurement of pulsatile total blood flow in the human and rat retina with ultrahigh speed spectral/Fourier domain OCT
نویسندگان
چکیده
We present an approach to measure pulsatile total retinal arterial blood flow in humans and rats using ultrahigh speed Doppler OCT. The axial blood velocity is measured in an en face plane by raster scanning and the flow is calculated by integrating over the vessel area, without the need to measure the Doppler angle. By measuring flow at the central retinal artery, the scan area can be very small. Combined with ultrahigh speed, this approach enables high volume acquisition rates necessary for pulsatile total flow measurement without modification in the OCT system optics. A spectral domain OCT system at 840nm with an axial scan rate of 244kHz was used for this study. At 244kHz the nominal axial velocity range that could be measured without phase wrapping was ±37.7mm/s. By repeatedly scanning a small area centered at the central retinal artery with high volume acquisition rates, pulsatile flow characteristics, such as systolic, diastolic, and mean total flow values, were measured. Real-time Doppler C-scan preview is proposed as a guidance tool to enable quick and easy alignment necessary for large scale studies. Data processing for flow calculation can be entirely automatic using this approach because of the simple and robust algorithm. Due to the rapid volume acquisition rate and the fact that the measurement is independent of Doppler angle, this approach is inherently less sensitive to involuntary eye motion. This method should be useful for investigation of small animal models of ocular diseases as well as total blood flow measurements in human patients in the clinic.
منابع مشابه
Functional imaging of hemodynamic stimulus response in the rat retina with ultrahigh-speed spectral / Fourier domain OCT
Measuring retinal hemodynamics in response to flicker stimulus is important for investigating pathophysiology in small animal models of diabetic retinopathy, because a reduction in the hyperemic response is thought to be one of the earliest changes in diabetic retinopathy. In this study, we investigated functional imaging of retinal hemodynamics in response to flicker stimulus in the rat retina...
متن کاملRetinal blood flow measurement with ultrahigh-speed swept-source / Fourier domain optical coherence tomography
Doppler OCT is a functional extension of OCT that provides information on flow in biological tissues. We present a novel approach for total retinal blood flow assessment using ultrahigh speed Doppler OCT. A swept source / Fourier domain OCT system at 1050 nm was used for 3D imaging of the human retina. The high axial scan rate of 200 kHz allowed measuring the high flow velocities in the central...
متن کاملTotal retinal blood flow measurement with ultrahigh speed swept source/Fourier domain OCT
Doppler OCT provides depth-resolved information on flow in biological tissues. In this article, we demonstrate ultrahigh speed swept source/Fourier domain OCT for visualization and quantitative assessment of retinal blood flow. Using swept laser technology, the system operated in the 1050-nm wavelength range at a high axial scan rate of 200 kHz. The rapid imaging speed not only enables volumetr...
متن کاملBlood flow measurement and slow flow detection in retinal vessels with Joint Spectral and Time domain method in ultrahigh speed OCT
We present an application of the Joint Spectral and Time domain OCT (STdOCT) method for detection of wide range of flows in the retinal vessels. We utilized spectral/Fourier domain OCT (SOCT) technique for development of scan protocols for Doppler signal analysis. We performed retinal imaging in normal eyes using ultrahigh speed (200 000 axial scans/s) SOCT instrument with a CMOS camera. Variou...
متن کاملUltrahigh speed spectral / Fourier domain ophthalmic OCT imaging
Ultrahigh speed spectral / Fourier domain optical coherence tomography (OCT) using a CMOS line scan camera with image acquisition rates of 70,000 312,500 axial scans per second is investigated. Several design configurations are presented to illustrate design trade-offs between acquisition speed, sensitivity, resolution and sensitivity roll-off performance. We demonstrate: extended imaging range...