Efficacy of alumina ceramic heads for cemented total hip arthroplasty.
نویسندگان
چکیده
Fifty-seven cemented total hip arthroplasties (THAs) were reviewed in cases of osteoarthrosis secondary to congenital dysplasia or dislocation. The bearing surface of the prosthesis used in this series consists of a polyethylene acetabular component on an alumina ceramic head. All acetabular components were positioned at the same level as the original acetabulum, and an autologous femoral head graft was performed for 18 hips. The follow-up period ranged from five to eight years, averaging six years two months. The latest survey showed excellent and good results for 53 hips (92.9%). Four acetabular components (7%) and two femoral components (3.5%) showed roentgenographic evidence of loosening. Only one hip (1.8%) had to be treated with revision surgery for femoral component loosening. None of the cases suffered a broken ceramic head. The use of a total hip prosthesis with an alumina ceramic head in THA is likely to lead to excellent results for patients with osteoarthrosis of the hip.
منابع مشابه
Effect of alumina femoral heads on polyethylene wear in cemented total hip arthroplasty. Old versus current alumina.
We examined the behaviour of alumina ceramic heads in 156 cemented total hip arthroplasties, at a minimum follow-up of eight years. They were divided into three groups according to the size of the femoral head; 22, 26, and 28 mm. We measured polyethylene wear radiologically using a computer-aided technique. The linear wear rate of polyethylene sockets for the 28 mm heads was high (0.156 mm/year...
متن کاملA comparison of polyethylene wear between cobalt-chrome ball heads and alumina ball heads after total hip arthroplasty: a 10-year follow-up
STUDY DESIGN This is a retrospective study comparing polyethylene wear between ceramic ball heads and metal ball heads in total hip arthroplasty. BACKGROUND The ceramic-on-polyethylene bearing option has been introduced as an alternative to metal-on-polyethylene to minimize polyethylene wear debris and reduce subsequent osteolysis and aseptic loosening. However, the reported data were debatab...
متن کامل4 . 1 Evolution of Total Hip Arthroplasty : Computer - Assisted , Minimally Invasive Techniques Combined with Alumina Ceramic - Ceramic Bearings
Total Hip Arthroplasty was initially introduced as a cemented construct with a metal femoral stem and a polyethylene acetabular component, performed through a transtrochanteric exposure. Over the ensuing thirty years, improvements to total hip arthroplasty have included the advent of uncemented acetabular and femoral components components and the popularization of alternative exposures includin...
متن کاملUse of an alumina ceramic-on-alumina ceramic bearing surface in THA in a 13 year old with JIA--a single case study.
Total hip arthroplasty (THA) has been shown to be highly effective in ameliorating pain and increasing function in adults with end stage arthritis of the hip. Early studies of cemented THA in children with advanced hip disease reported poor results, but, more recently, results of cementless THA show greatly improved outcomes. More recently, concerns related to THA in children have focused on we...
متن کاملAlumina-on-alumina total hip replacement for femoral neck fracture in healthy patients
BACKGROUND Total hip replacement is considered the best option for treatment of displaced intracapsular fractures of the femoral neck (FFN). The size of the femoral head is an important factor that influences the outcome of a total hip arthroplasty (THA): implants with a 28 mm femoral head are more prone to dislocate than implants with a 32 mm head. Obviously, a large head coupled to a polyethy...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical orthopaedics and related research
دوره 283 شماره
صفحات -
تاریخ انتشار 1992