Comparison of the ramp versus standard exercise protocols.

نویسندگان

  • J Myers
  • N Buchanan
  • D Walsh
  • M Kraemer
  • P McAuley
  • M Hamilton-Wessler
  • V F Froelicher
چکیده

To compare the hemodynamic and gas exchange responses of ramp treadmill and cycle ergometer tests with standard exercise protocols used clinically, 10 patients with chronic heart failure, 10 with coronary artery disease who were asymptomatic during exercise, 11 with coronary artery disease who were limited by angina during exercise and 10 age-matched normal subjects performed maximal exercise using six different exercise protocols. Gas exchange data were collected continuously during each of the following protocols, performed on separate days in randomized order: Bruce, Balke and an individualized ramp treadmill; 25 W/stage, 50 W/stage and an individualized ramp cycle ergometer test. Maximal oxygen uptake was 16% greater on the treadmill protocols combined (21.4 +/- 8 ml/kg per min) versus the cycle ergometer protocols combined (18.1 +/- 7 ml/kg per min) (p less than 0.01), although no differences were observed in maximal heart rate (131 +/- 24 versus 126 +/- 24 beats/min for the treadmill and cycle ergometer protocols, respectively). No major differences were observed in maximal heart rate or maximal oxygen uptake among the various treadmill protocols or among the various cycle ergometer protocols. The ratio of oxygen uptake to work rate, expressed as a slope, was highest for the ramp tests (slope +/- SEE ml/kg per min = 0.80 +/- 2.5 and 0.78 +/- 1.7 for ramp treadmill and ramp cycle ergometer, respectively). The slopes were poorest for the tests with the largest increments in work (0.62 +/- 4.0 and 0.59 +/- 2.8 for the Bruce treadmill and 50 W/stage cycle ergometer, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A nomogram to select the optimal treadmill ramp protocol in subjects with high exercise capacity: validation and comparison with the Bruce protocol.

PURPOSE Guidelines suggest that individualized ramp protocols with treadmill times targeted between 8 and 12 minutes are most suitable to estimate exercise capacity. However, previous methods to determine individualized ramp rates and comparisons between ramp and standardized protocols have been limited to clinically referred populations. METHODS Forty-three healthy volunteers [median (interq...

متن کامل

Comparison of the peak exercise response measured by the ramp and 1-min step cycle exercise protocols in patients with exertional dyspnea.

STUDY OBJECTIVES To compare the peak exercise response and determine the limits of agreement between the ramp and the 1-min step cycle protocols in a representative population of patients with exertional breathlessness attending a respiratory outpatient clinic. DESIGN Crossover with the test order double blinded and randomized. SETTING Outpatient exercise physiology laboratory. PATIENTS T...

متن کامل

Exercise Maximum Capacity Assessment: A Review on the Traditional Protocols and the Evolution to Individualized Models

Mailing address: Paulo de Tarso Veras Farinatti Laboratório de Atividade Física e Promoção da Saúde (LABSAU), Instituto de Educação Física e Desportos, Universidade do Estado do Rio de Janeiro Rua São Francisco Xavier, 524, 8o andar, salas 8.121-F e 8.133-F 20550-013 – Rio de Janeiro, RJ, Brazil. E-mail: [email protected] ABSTRACT The physiological adjustments to exercise have been extensively i...

متن کامل

Assessment of peak oxygen uptake during handcycling: Test-retest reliability and comparison of a ramp-incremented and perceptually-regulated exercise test

PURPOSE To examine the reliability of a perceptually-regulated maximal exercise test (PRETmax) to measure peak oxygen uptake ([Formula: see text]) during handcycle exercise and to compare peak responses to those derived from a ramp-incremented protocol (RAMP). METHODS Twenty recreationally active individuals (14 male, 6 female) completed four trials across a 2-week period, using a randomised,...

متن کامل

Effect of A Slow Ramp Rate on Exercise Testing: A Healthy Volunteer Study

Ramp rates for incremental ramp rate exercise testing are not standardised. The ramp rate may influence the values obtained during exercise testing. We compared a slow ramp rate (SR) (3watts/minute) to a fast ramp rate (FR) (20 watts/minute) in 8 fit non elite cyclists using cycle ergometry. We measured peak power ,oxygen consumption (VO2) at anaerobic threshold (AT) and maximum aerobic capacit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 17 6  شماره 

صفحات  -

تاریخ انتشار 1991