Inter-Rectus Distance Measurement Using Ultrasound Imaging: Does the Rater Matter?
نویسندگان
چکیده
Purpose: To investigate the interrater reliability of inter-rectus distance (IRD) measured from ultrasound images acquired at rest and during a head-lift task in parous women and to establish the standard error of measurement (SEM) and minimal detectable change (MDC) between two raters. Methods: Two physiotherapists independently acquired ultrasound images of the anterior abdominal wall from 17 parous women and measured IRD at four locations along the linea alba: at the superior border of the umbilicus, at 3 cm and 5 cm above the superior border of the umbilicus, and at 3 cm below the inferior border of the umbilicus. The interrater reliability of the IRD measurements was determined using intra-class correlation coefficients (ICCs). Bland-Altman analyses were used to detect bias between the raters, and SEM and MDC values were established for each measurement site. Results: When the two raters performed their own image acquisition and processing, ICCs(3,5) ranged from 0.72 to 0.91 at rest and from 0.63 to 0.96 during head lift, depending on the anatomical measurement site. Bland-Altman analyses revealed no systematic bias between the raters. SEM values ranged from 0.23 cm to 0.71 cm, and MDC values ranged from 0.64 cm to 1.97 cm. Conclusion: When using ultrasound imaging to measure IRD in women, it is acceptable for different therapists to compare IRDs between patients and within patients over time if IRD is measured above or below the umbilicus. Interrater reliability of IRD measurement is poorest at the level of the superior border of the umbilicus.
منابع مشابه
Inter-rater reliability of ultrasound imaging of the trunk musculature among novice raters.
OBJECTIVE The purpose of this study was to determine the inter-rater reliability of ultrasound imaging for assessing trunk muscle morphologic characteristics at rest and while contracted among different pairs of novice raters. The secondary purpose was to compare 3 different measurement techniques for assessing lateral abdominal muscle thickness. METHODS A single-group repeated measures relia...
متن کاملMusculoskeletal diagnostic ultrasound imaging for thickness measurement of four principal muscles of the cervical spine -a reliability and agreement study
BACKGROUND The reliability of musculoskeletal diagnostic ultrasound imaging (MSK-DUSI) for the evaluation of neck musculature has been sparsely documented in the research literature. Until now, research has featured a limited number of subjects and only few studies have tested for both inter- and intra-reliability using appropriate methodology. METHODS Four examiners conducted an inter- and i...
متن کاملReliability of ultrasound imaging in the assessment of the dorsal Lisfranc ligament
BACKGROUND The Lisfranc ligament plays an integral role in providing stability to the midfoot. Variable clinical presentations and radiographic findings make injuries to the Lisfranc ligament notoriously difficult to diagnose. Currently, radiographic evaluation is the mainstay in imaging such injuries; however, ultrasound has been suggested as a viable alternative. The objective of this study w...
متن کاملComparative study of linear and curvilinear ultrasound probes to assess quadriceps rectus femoris muscle mass in healthy subjects and in patients with chronic respiratory disease.
INTRODUCTION Ultrasound measurements of rectus femoris cross-sectional area (RFCSA) are clinically useful measurements in chronic obstructive pulmonary disease (COPD) and critically ill patients. Technical considerations as to the type of probe used, which affects image resolution, have limited widespread clinical application. We hypothesised that measurement of RFCSA would be similar with line...
متن کاملReliability of ultrasound in combination with surface electromyogram for evaluating the activity of abdominal muscles in individuals with and without low back pain
This study investigated the reliability of ultrasound in combination with surface electromyogram (EMG) for evaluating the activity of the abdominal muscles in individuals with and without low back pain during the abdominal drawing-in maneuver (ADIM). The study recruited ten individuals with or without low back pain, respectively. While the participants were performing the ADIM, the activities o...
متن کامل