T2 relaxometry of the hippocampus at 3T.

نویسندگان

  • P A Bartlett
  • M R Symms
  • S L Free
  • J S Duncan
چکیده

BACKGROUND AND PURPOSE T2 mapping is useful for identifying and quantifying abnormalities of the hippocampus and amygdala. It is particularly useful in the presurgical evaluation of patients with temporal lobe epilepsy and for the identification of bilateral hippocampal sclerosis (HS). The purpose of this study was to implement and validate a dual-echo method for producing coronal T2 maps with complete coverage of the hippocampus and the rest of the brain on a 3T MR imaging scanner. MATERIALS AND METHODS T2 relaxation times were estimated on 10 occasions on 3 quality assessment Eurospin II (Diagnostic Sonar, Livingstone, Scotland) test objects with the use of conventional spin-echo (CSE), fast spin-echo, and fast recovery fast spin-echo (FRFSE) sequences on a 3T Excite MR imaging scanner (GE Healthcare, Milwaukee, Wis). Hippocampal T2 relaxation times were then measured in 15 healthy subjects and 20 subjects with clear-cut HS who were scanned at 1.5 T with a previously validated dual-echo CSE sequence and 3T with an FRFSE sequence. RESULTS 3T FRFSE data were as reliable as CSE data at 1.5 T. Reliability of hippocampal T2 measures was good on healthy volunteers and subjects with HS. FRFSE images were suitable for qualitative radiologic reporting and with complete brain coverage, so no additional T2-weighted sequences were required. There was good correlation between the 3T hippocampal T2 measurements and values obtained with the previously validated technique at 1.5 T, with reliable identification of all of the subjects with HS. CONCLUSIONS T2 mapping with an FRFSE 30/80 sequence may be readily applied at 3T and can produce reliable T2 values in vivo with contiguous 5-mm sections and in a much reduced scan time of 3 minutes 1 second compared with 10 minutes 30 seconds for the CSE sequence at 1.5 T.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3T MRI quantification of hippocampal volume and signal in mesial temporal lobe epilepsy improves detection of hippocampal sclerosis.

BACKGROUND AND PURPOSE In mesial temporal lobe epilepsy, MR imaging quantification of hippocampal volume and T2 signal can improve the sensitivity for detecting hippocampal sclerosis. However, the current contributions of these analyses for the diagnosis of hippocampal sclerosis in 3T MRI are not clear. Our aim was to compare visual analysis, volumetry, and signal quantification of the hippocam...

متن کامل

Relative localizing value of amygdalo-hippocampal MR biometry in temporal lobe epilepsy.

OBJECTIVES The aims of the study were (i) to examine the localizing value of three MRI quantitative modalities (qMRI) currently used for the analysis of the hippocampus and amygdala in the context of pre-surgical screening and (ii) to propose a step-by-step protocol based on the sensitivity and performance of the different MR techniques. METHODS Ninety-two adults with chronic mesial temporal ...

متن کامل

T1 at 1.5T and 3T compared with conventional T2* at 1.5T for cardiac siderosis

BACKGROUND Myocardial black blood (BB) T2* relaxometry at 1.5T provides robust, reproducible and calibrated non-invasive assessment of cardiac iron burden. In vitro data has shown that like T2*, novel native Modified Look-Locker Inversion recovery (MOLLI) T1 shortens with increasing tissue iron. The relative merits of T1 and T2* are largely unexplored. We compared the established 1.5T BB T2* te...

متن کامل

Increased anterior temporal lobe T2 times in cases of hippocampal sclerosis: a multi-echo T2 relaxometry study at 3 T.

BACKGROUND AND PURPOSE Increased T2 relaxation times in the ipsilateral hippocampus are present in patients with hippocampal sclerosis. Visual assessment of T2-weighted images of these patients suggests increased signal intensity in the anterior temporal lobe as well. Our aim was to assess hippocampal and anterior temporal T2 relaxation times in patients with partial epilepsy by using a new T2-...

متن کامل

Myocardial iron assessment by T1 cardiovascular magnetic resonance at 3 Tesla

Background Myocardial T2* relaxometry at 1.5T provides reliable non-invasive assessment of cardiac iron burden and is commonly used for the diagnosis and monitoring of patients at risk. 3T CMR offers some advantages over 1.5T but iron assessment has not been routinely performed at 3T due to technical concerns regarding artefacts and rapid signal loss, as well as a lack of tissue calibration. In...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 28 6  شماره 

صفحات  -

تاریخ انتشار 2007