Hepatic MR imaging with 3D Gradient Echo: Linear Cartesian k-space ordering with partial scan along both slice and phase direction

نویسندگان

  • K. Kim
  • M-J. Kim
  • G. Herigault
  • Y. Chung
چکیده

Introduction: 3D gradient echo (GRE) sequence is commonly used for T1-weighted MR imaging of liver. Conventional 3D GRE sequences utilize either one of centric-linear, radial or linear ordering of k-space with a fat suppression technique and partial scan technique along a slice direction. We introduce a enhanced 3D-GRE sequence, which adopted a linear ordering with half scan along both slice and phase directions, and matched turbo scan factor with the number of slices. We compared conventional and enhanced 3D T1-weighted GRE sequences in terms of image quality and conspicuity of liver lesions. Methods: 39 consecutive patients suspected with liver lesions underwent hepatic MR examinations on 3.0-T system. Conventional 3D GRE sequence using radial ordering of k-space with partial scan along slice direction and ‘enhanced’ 3D GRE sequence using linear Carteisan k-space ordering and partial scan along both slice and phase direction were compared. In both sequence fat signal was suppressed using a spectral inversion recovery pulse. Conventional and enhanced 3D GRE images were obtained for precontrast images in 32 patients and for gadoxate disodium (EOB)-enhanced hepatobiliary phase images in 39 patients. For qualitative analysis, two reviewers jointly reviewed the conventional and enhanced 3D GRE images and recorded the grades of anatomic sharpness, overall contrast, homogeneity, and absence of artifacts in one of four scales (0-4) for both precontrast and postcontrast images. For quantitative analysis, one reviewer measured liver-to-lesion signal difference ratio (SDR) in one lesion in each patient who had lesions larger than 1 cm in diameter. Liver-to-spleen SDR was also measured for all patients. Interval values from qualitative analysis were compared by using paired sample Wilcoxon test. Liver-to-lesion and liver-to-spleen SDR were compared by using paired t-test. Results: Compared to conventional 3D-GRE images, enhanced 3D-GRE images showed significantly higher liver-to-spleen SDR (P=0.0464) and liver-to-lesion SDR (P=0.0004) on EOB-enhanced images, but not on precontrast images. In qualitative analysis of the precontrast images, enhanced 3D-GRE images showed significantly better than conventional 3D-GRE images in terms of the anatomic sharpness, overall contrast, homogeneity, and absence of artifacts (P<0.05). In a comparison of EOB-enhanced MRI, enhanced 3D-GRE images showed better quality in terms of overall contrast, homogeneity and absence of artifacts (p<0.05).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compressed Sensing for Motion Artifact Reduction

Introduction: Navigators can effectively track rigid-body motion of limited amplitude, such as respiratory motion [1,2,3]. In a Cartesian scan, data is corrected by applying to each k-space line the phase modulation corresponding to the amount of detected motion. However, lines associated with significant motion (e.g., swallowing in larynx imaging) are uncorrectable and therefore need to be dis...

متن کامل

Compressive Slice Encoding for Metal Artifact Correction

Introduction: Slice encoding for metal artifact correction (SEMAC) [1] completely corrects metal-induced in-plane and through-plane distortions. The SEMAC imaging sequence (Fig. 1) augments a view-angle-tilting (VAT) [2] spin echo sequence with z-phase encoding. While the VATcompensation gradient suppresses the in-plane distortions, the throughplane distortions are corrected by combining multip...

متن کامل

Arterial-phase Bolus-track Liver Examination (ABLE): Optimization of Liver Arterial Phase Gadolinium Enhanced MRI Using Centric Re-ordered 3D Gradient Echo and Bolus Track Real-Time Imaging

P. Sharma, J. De Becker, G. M. Beck, H. Friel, B. Burrow, D. Martin Radiology, Emory University, Atlanta, GA, United States, Philips Medical Systems, Best, Netherlands, Philips Medical Systems, Cleveland, OH, United States Introduction: It has been shown that amongst the most critical component of a comprehensive abdominal MRI of the liver is the arterial phase of a dynamically gadolinium enhan...

متن کامل

Sodium MRI of the human heart at 7.0 T: preliminary results.

The objective of this work was to examine the feasibility of three-dimensional (3D) and whole heart coverage (23)Na cardiac MRI at 7.0 T including single-cardiac-phase and cinematic (cine) regimes. A four-channel transceiver RF coil array tailored for (23)Na MRI of the heart at 7.0 T (f = 78.5 MHz) is proposed. An integrated bow-tie antenna building block is used for (1)H MR to support shimming...

متن کامل

3D Magnetization-Prepared Imaging and Fat/Water Separation Using a Stack-of-Rings Trajectory

Introduction: Acquiring a 3D volume in a short scan time is a high-priority goal of many MR imaging applications. This is especially true for time-sensitive studies, such as magnetization-prepared imaging and dynamic imaging, where the signal is in transition. Fast imaging trajectories, such as under-sampled 3DPR or 3D stack-ofspirals, can provide a great reduction in scan time. However, they a...