Automated estimation of urinary calcium using the Eppendorf flame photometer.

نویسنده

  • A M Bold
چکیده

A method is described for estimating urine calcium on a mechanized Eppendorf flame photometer with twin channels at a rate of 60 per hour. Sodium is estimated simultaneously so that a correction can be made for the small sodium error. Errors due to potassium and phosphate are minimized by adding these ions to the standards and to the diluting fluid. Results agree well with those obtained by Trinder's naphthal-hydroxamic acid precipitation method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated Estimation of Sodium, Potassium, and Calcium Using the Eppendorf Flame Photometer.

An Eppendorf flame photometer may be used to estimate sodium, potassium, and calcium in plasma which has been automatically sampled and diluted. Readings may be automatically recorded by feeding the output from the photomultiplier into a sensitive recorder. This method estimates 60 samples an hour, using approximately 0.12 ml. plasma per estimation. The accuracy of the method is discussed.

متن کامل

Serum Calcium Using the Eel Flame Photometer

Flame photometry has many applications, and in the clinical field its use in the estimation of serum sodium and potassium is now well established. Difficulties have been encountered in the estimation of serum calcium by flame photometry, since the emission spectrum of calcium is relatively weak and is subject to interference by the presence of other ions, e.g., sodium. Although many methods hav...

متن کامل

Use of silicon photovoltaic cells to provide a second channel in flame emission photometry.

Sodium and potassium may be measured simultaneously, using a modified Eppendorf flame photometer. After automatic sampling and dilution of the plasma, the potassium content is measured, using the existing Eppendorf optical and photomultiplier system. The sodium emission is measured by three silicon photovoltaic cells mounted behind an interference filter for sodium, sited on the atomiser casing...

متن کامل

An Automated Method for Serum Magnesium Estimation.

An automated method for magnesium determination in serum is described using conventional AutoAnalyser equipment. The method gives results comparable with those obtained by the flame photometer. The method may prove particularly useful with subnormal serum magnesium levels.

متن کامل

An improved flame-photometric method for determining calcium in serum.

Powell (1953) introduced a method for the estimation of serum calcium using the EEL flame photometer, and claimed that it gave results in good agreement with a standard titrimetric procedure. In this laboratory, both these methods were found to give low results when tested against standard sera, prepared by adding known amounts of calcium to serum completely decalcified by treatment with a cati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 19 6  شماره 

صفحات  -

تاریخ انتشار 1966