چکیده

Background and purpose: Although intensity modulated radiotherapy (IMRT) is a step forward in comparison to conventional, static beam delivery, quality assurance is more complex and labour intensive, demanding detailed two-dimensional dosimetric verification. Regardless of the technique used for measuring the dose distribution, what is essential to the implementation of routine verification of IMRT fields is the efficient and accurate comparison of the measured versus desired dose distribution. In order to achieve a fast, yet accurate quantitative measure of the correspondence between measured and calculated dose, the theoretical concept of the gamma evaluation method presented by Low et al. (Med. Phys., 25 (1998) 656) was converted into a calculation algorithm, taking into account practical considerations related to the discrete nature of the data. Materials and methods: A filter cascade of multiple levels was designed to obtain fast and accurate comparison of the two dose distributions under evaluation. The actual comparison consists of classification into accepted or rejected datapoints with respect to userdefined acceptance criteria (dose difference and distance to agreement). The presented algorithm was tested on dosimetric images calculated and/or acquired by means of a liquid filled portal imaging device during the course of intensity modulated treatments of prostate cancer, including pre-treatment verification as well as verification during treatment. To assess its ability to intercept possible errors in dose delivery, clinically relevant errors were deliberately introduced into the dose distributions. Results: The developed gamma filter method proves successful in the efficient comparison of calculated versus measured IMRT dose distribution. Secondly, intercomparison of dosimetric images acquired during different treatment sessions illustrate its potential to highlight variations in the dosimetric images. The simulated errors were unmistakably intercepted. Conclusions: The readily obtained gamma evaluation images are an easy tool for quality control of IMRT fields. To reduce the artefacts related to the discrete nature and limited resolution of the data, a fast and accurate filter cascade was developed, offering the possibility to use the gamma method for day to day evaluation of patient dosimetric portal images with or without comparison to a predicted portal dose distribution. q 2002 Elsevier Science Ireland Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pii: S0167-8140(01)00377-2

Background and purpose: To design a consistent set of criteria for acceptability of photon beam dose calculations of treatment planning systems. The set should be applicable in combination with a test package used for evaluation of a treatment planning system, such as the ones proposed by the AAPM Task Group 23 or by the Netherlands Commission on Radiation Dosimetry. Results: Tolerances have be...

متن کامل

Pii: S0167-8140(01)00425-x

Background and purpose: Only limited data exist on the outcome of curative radiotherapy in patients who develop a second primary lung tumour after pneumonectomy. The treatment of eight such patients is described. Materials and methods: The case records of patients who underwent curative radiotherapy for stage I non-small cell lung cancer after a previous pneumonectomy were reviewed. Treatment w...

متن کامل

Neural Mechanisms for the Generation of Visual Complex Cells

In 1962, Hubel and Wiesel reported what they later described as "the first description of a clear function for the cerebral cortex, in terms of clear differences between input and output". Martinez and Alonso (2001[this issue of Neuron]) now provide evidence for the hierarchical neural circuit that Hubel and Wiesel proposed to explain the cortical transformation from simple to complex cells.

متن کامل

Auxin transport: Why plants like to think BIG

The regulation of auxin transport via auxin efflux carriers likely plays a central role in a variety of physiological responses in higher plants. With the isolation of BIG, an Arabidopsis protein of enormous size, another potential regulator of auxin transport has been characterized.

متن کامل

Pii: S0167-2231(01)00041-0

We construct a random matching model to study the effects of clearing arrangements for private money on the prices at which private monies trade, the volume of exchange, and welfare. In a model with full information, clearing arrangements eliminate discounts on private monies issued in other locations, the volume of exchange increases, and welfare increases. However, with private information ab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002