Clinical significance of superior articular process as a reference point for free-hand pedicle screw insertion in thoracic spine

نویسندگان

  • Tae Hoon Kim
  • Suk Ha Lee
  • Jae Hyuk Yang
  • Jae Young Hong
  • Seung Woo Suh
چکیده

The trajectory of the pedicle screw perpendicular to the SAP (superior articular process) is consistent with the universal trajectory presented in the previous study of the entry point using computed tomography. The ideal entry point and trajectory of pedicle screw insertion have been a matter of considerable debate. We attempted to find the relationship between SAP and entry point and trajectory of the pedicle screw.Thoracic spine CT (computed tomography) scans of 9 volunteers were studied. A safe zone for the trajectory of the screw in the axial (MarginAx) and sagittal (MarginSag) was defined as the zone between lines perpendicular to the SAP along the medial and lateral cortex of the pedicle in the axial section, and the superior and inferior cortex in the sagittal section without violation of the pedicle walls. The midline of MarginAx and MarginSag was defined as the safe entry point of the trajectory in the axial and sagittal planes (TrajectoryAx and TrajectorySag), respectively.MarginAx and MarginSag were 4.14 ± 0.99 and 9.03 ± 2.01 mm, respectively. There was a statistically significant difference in TrajectoryAx between the upper and middle, and between the upper and lower (P = .0076 in both cases), but not between the middle and lower thoracic spine (P = .066). TrajectorySag was within 1 mm at the levels of T4, T8, T11 vertebrae and at 0 mm at the other levels. Thus, the midpoint of MarginSag was within 1 mm from the SAP base.There was a constant angular relationship with the SAP and the pedicle axis; the line perpendicular to the SAP can act as a trajectory. Therefore, we suggest that the SAP might be the only accurate and safe reference for pedicle screw insertion in the thoracic spine perpendicular to the SAP using freehand technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

Cadaveric study for ideal dorsal pedicle screw entry point

OBJECTIVE To determine the entry for the dorsal pedicular screw in relation to the notch present at the junction of base of the lateral margin of superior articular process with superior border of transverse process in dorsal spine. The advantage of this technique is a constant and easily identifiable entry point which does not involve partial resection of the inferior facet, thus maintaining s...

متن کامل

Free Hand Pedicle Screw Placement in the Thoracic Spine without Any Radiographic Guidance : Technical Note, a Cadaveric Study

Thoracic pedicle screw fixation techniques are still controversial for thoracic deformities because of possible complications including neurologic deficit. Methods to aid the surgeon in appropriate screw placement have included the use of intraoperative fluoroscopy and/or radiography as well as image-guided techniques. We describe our technique for free hand pedicle screw placement in the thora...

متن کامل

Novel Landmark for Cervical Pedicle Screw Insertion Point from Computed Tomography-Based Study

STUDY DESIGN Cross-sectional study. PURPOSE The purpose of this study was to evaluate a novel landmark for the cervical pedicle screw insertion point. OVERVIEW OF LITERATURE To improve the accuracy of pedicle screw placement, several studies have employed the lateral mass, lateral vertical notch, and/or inferior articular process as landmarks; however, we often encounter patients in whom we...

متن کامل

Accuracy of Free Hand Pedicle Screw Installation in the Thoracic and Lumbar Spine by a Young Surgeon: An Analysis of the First Consecutive 306 Screws Using Computed Tomography

STUDY DESIGN A retrospective cross-sectional study. PURPOSE The purpose of this study is to evaluate the accuracy and safety of free-hand pedicle screw insertion performed by a young surgeon. OVERVIEW OF LITERATURE Few articles exist regarding the safety of the free-hand technique without inspection by an experienced spine surgeon. METHODS The index surgeon has performed spinal surgery fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 97  شماره 

صفحات  -

تاریخ انتشار 2018