Breathhold three-dimensional coronary magnetic resonance angiography using real-time navigator technology.

نویسندگان

  • M Stuber
  • R M Botnar
  • P G Danias
  • K V Kissinger
  • W J Manning
چکیده

The acquisition duration of most three-dimensional (3D) coronary magnetic resonance angiography (MRA) techniques is considerably prolonged, thereby precluding breathholding as a mechanism to suppress respiratory motion artifacts. Splitting the acquired 3D volume into multiple subvolumes or slabs serves to shorten individual breathhold duration. Still, problems associated with misregistration due to inconsistent depths of expiration and diaphragmatic drift during sustained respiration remain to be resolved. We propose the combination of an ultrafast 3D coronary MRA imaging sequence with prospective real-time navigator technology, which allows correction of the measured volume position. 3D volume splitting using prospective real-time navigator technology, was successfully applied for 3D coronary MRA in five healthy individuals. An ultrafast 3D interleaved hybrid gradient-echoplanar imaging sequence, including T2Prep for contrast enhancement, was used with the navigator localized at the basal anterior wall of the left ventricle. A 9-cm-thick volume, with in-plane spatial resolution of 1.1 x 2.2 mm, was acquired during five breathholds of 15-sec duration each. Consistently, no evidence of misregistration was observed in the images. Extensive contiguous segments of the left anterior descending coronary artery (48 +/- 18 mm) and the right coronary artery (75 +/- 5 mm) could be visualized. This technique has the potential for screening for anomalous coronary arteries, making it well suited as part of a larger clinical MR examination. In addition, this technique may also be applied as a scout scan, which allows an accurate definition of imaging planes for subsequent high-resolution coronary MRA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional gadolinium-enhanced coronary magnetic resonance angiography: initial experience.

We present our initial experience on first-pass gadolinium-enhanced coronary artery magnetic resonance angiography (MRA). Three-dimensional segmented gradient-echo sequences were developed to image coronary arteries within a single breathhold during the injection of a double-dose contrast agent. Comparisons were made between a short TR of 2.7-msec (n = 5) and a long TR of 5.0-msec (n = 3) seque...

متن کامل

Compression belt for navigator-triggered trueFISP whole-heart coronary magnetic resonance angiography: study in healthy volunteers.

PURPOSE To evaluate in healthy volunteers the usefulness of an abdominal compression belt in reducing acquisition time by stabilizing respiratory motion during whole-heart coronary magnetic resonance angiography (WHCMRA) using conventional navigator triggering. METHODS In 10 healthy volunteers, we performed free-breathing 3-dimensional segmented true fast imaging with steady-state precession ...

متن کامل

Calculation of a subject-specific adaptive motion-correction factor for improved real-time navigator echo-gated magnetic resonance coronary angiography.

There has been conflicting data in the literature regarding the use of wide navigator echo (NE) acceptance windows in combination with adaptive motion correction for magnetic resonance coronary angiography (MRCA). This in part may be due to the use of a fixed correction factor when applying the adaptive motion-correction algorithm, which may potentially result in miscorrection of the imaging sl...

متن کامل

Detection of coronary stenoses with contrast enhanced, three-dimensional free breathing coronary MR angiography using the gadolinium-based intravascular contrast agent gadocoletic acid (B-22956).

PURPOSE To determine the diagnostic value of the intravascular contrast agent gadocoletic acid (B-22956) in three-dimensional, free breathing coronary magnetic resonance angiography (MRA) for stenosis detection in patients with suspected or known coronary artery disease. METHODS Eighteen patients underwent three-dimensional, free breathing coronary MRA of the left and right coronary system be...

متن کامل

Real-Time Navigator Approach to Motion Problems in Coronary MRA

This paper is a summary discourse on the real time navigator approach to suppressing motion effects in coronary magnetic resonance angiography. The concept of navigator approach, characteristics of coronary motion, design of navigator echoes for motion measurements, and navigator algorithms for motion effects suppression are reviewed and discussed. At the conclusion, an efficient and effective ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance

دوره 1 3  شماره 

صفحات  -

تاریخ انتشار 1999