Surface topography scan as a source for orthotic brace design. Technique and case presentation
نویسندگان
چکیده
Material and methods Computer Aided Design and Manufacturing in bracing is based on the introduction of appropriate data to the computer using anthropometry. The best data can be delivered by precise 3D surface topography supplemented with Xray and other necessary radiographic modalities. The surface topography scanning used for this study is based on structured light projection. Scanning the surface of the patient’s body is carried out using the multi-directional laboratory scanning system, located at the Baby Jesus Clinical Hospital. The scanning system consists of four unidirectional systems. Each system is calibrated in a common coordinate system and a PC computing unit. Each unit includes a digital camera, multimedia projector and independent PC operating for the projection and recording of images (raster images and binary sinusoidal modulation of brightness). Raster images are recorded by the camera and processed by the scanner’s software. It allows extracting the 3D shape of the patient’s image of the torso surface. The total time of image acquisition is approximately 1.5 seconds. It can be further modified by the orthotist. The positive, foam torso model can be manufactured upon approval and acceptance. The measurement data are obtained in the form of a point cloud further converted into a 3D model in STL format for further manufacture the orthosis. Point cloud accuracy is as high as less than 0.5 mm. The methodology is described based on the real AIS case. Results and conclusion The case of 12 years old AIS female patient was documented while elaboration the 3D scan and manufacturing of the brace based on STL file derived from 3D point cloud. Presented approach shows the implementation of the 3D surface topography scanning and its opportunity to transform it easy into a brace design suitable for TLSO brace manufacturing. Good fit and function today remains an important issue in brace manufacturing. We believe that 3D 360 degrees surface scan may significantly improve the accuracy of individual brace production.
منابع مشابه
Improved brace design combining CAD/CAM and finite element simulation for the conservative treatment of adolescent idiopathic scoliosis (AIS): preliminary results of a randomized control trial
Polytechnique Montreal, Montreal, Canada Full list of author information is available at the end of the article Figure 1 A) Acquisition of the internal geometry using the calibrated bi-planar radiographic 3D reconstruction technique; B) Acquisition of the external geometry using a surface topography system or a scan system; C) Internal 3D geometry; D) External 3D geometry E) Geometric registrat...
متن کاملImmediate correction required to expect a long-term effectiveness of a brace treatment: a biomechanical insight
Methods The three-dimensional geometry of 30 patients was acquired using multi-view radiographic reconstruction and surface topography techniques. A finite element model of the trunk and a parametric brace model were created. For each case, two spinal stiffnesses (flexible, stiff) were tested. Installation of the brace was simulated. Using an experimental design framework including thirteen des...
متن کاملCombined effects of a valgus knee brace and lateral wedge foot orthotic on the external knee adduction moment in patients with varus gonarthrosis.
OBJECTIVE To test the hypothesis that a custom-fit valgus knee brace and custom-made lateral wedge foot orthotic will have greatest effects on decreasing the external knee adduction moment during gait when used concurrently. DESIGN Proof-of-concept, single test session, crossover trial. SETTING Biomechanics laboratory within a tertiary care center. PARTICIPANTS Patients (n=16) with varus ...
متن کاملCoronal plane alignment in orthotic treatment of adolescent idiopathic scoliosis: evaluation of balance parameters in orthotic outcomes
Materials and methods This is a retrospective study examining coronal plane spine radiographs of 27 adolescents diagnosed with idiopathic scoliosis and prescribed a Boston Brace-style thoracolumbosacral orthosis. Cobb angle, decompensation of C7, and Overall Balance Summation (OBS) (Carlson and Smith, 2007) were measured on pre-brace, in-brace, and immediately post-brace x-rays for each subject...
متن کاملA statistic approach to electronic moulding versus traditional plaster moulding
Results 1) The average initial angle is: 28,19 (+-9,21) for thoracic, 28,11 (+-9,34) for thoraco-lumbar and 25,86 (+-7,04) for lumbar curves. 2) The angular reducibility is 54 % in braces for the thoracic curvatures, 69 % for the thoraco-lumbar curvatures and of 73 % for the lumbar curvatures, which corresponds to the usual results of the Lyon management. If we select curves of 30° and more the...