Comparison of the VISX wavescan and OPD-scan III with the subjective refraction.

نویسندگان

  • R Zhu
  • K-L Long
  • X-M Wu
  • Q-D Li
چکیده

OBJECTIVE To compare the refractive errors measured by the VISX WaveScan, OPD-Scan III and the subjective refraction. The optometry accuracy of computer operated aberrometer used before refractive surgery has been debatable. Hence, a clear study on the role of such automated equipment in optometry is the need of the hour as compared to subjective refraction. PATIENTS AND METHODS Seventy-six patients (152 eyes) were recruited from January 2013 to December 2013. All patients were measured with subjective refraction by the phoropter (NIDEK, RT-5100), objective refraction by the WaveScan (AMO Company, USA), OPD-Scan III (Nidek Technologies, Japan). The sphere, cylinder, axis of the three methods were compared and analyzed. RESULTS The diopter of sphere power measured by WaveScan was lower than that of the subjective refraction and the difference was 0.13 ± 0. 30D (t = 3. 753, p <0. 001). While the diopter of cylinder power was higher and the difference was 0.13 ±0.43D (t = 3. 664, p <0. 001). There was no significance for sphere, cylinder and spherical equivalent between OPD-Scan III and subjective refraction (p >0. 05). The value of the difference between WaveScan and subjective refraction was 5.87°±6.19°on average, while the difference between OPD-Scan III and subjective refraction was 3.82°±3.95°on average. The differences between the two were statistically significant (t =2. 817, p =0. 006). CONCLUSIONS The results of sphere and cylinder measured by WaveScan and subjective refraction were different. As the latest integrated equipment, the Nidek OPD-Scan III gives a more accurate measurement of objective refraction when compared with subjective refraction. The latest Nidek OPD-Scan III may prove to be an useful tool for preoperative optometry deviation based on objective refraction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Higher order aberrations using the NIDEK OPD-Scan and AMO WaveScan.

PURPOSE To compare higher order aberrations measured with the NIDEK OPD-Scan and AMO WaveScan. METHODS Third- to sixth-order higher order aberrations were measured in 1072 eyes using the OPD-Scan and WaveScan. Means, standard deviations, confidence intervals, limits of agreement, and intraclass correlation coefficients (ICC) were calculated. RESULTS Aberrations of greatest magnitude with th...

متن کامل

Comparison of refractive assessment by wavefront aberrometry, autorefraction, and subjective refraction.

PURPOSE To compare refractive assessment results obtained with an aberrometer, an autorefractor, and manual subjective refraction (SR) in a healthy population with optimal visual potential. METHODS Sixty adults aged 18-59 years with visual acuity of 20/25 or better, no media opacity, and no known corneal or retinal abnormalities were recruited during the course of routine eye examination. Ref...

متن کامل

پیش بینی عیب انکساری بر اساس حدت بینایی با استفاده از چارت اسنلن و دستگاه OPD-scanIII

هدف: دستگاه OPD-scan III (Optical Path Difference Scanning System) تنها دستگاهی است که حدت بینایی آبجکتیو (Objective) را به صورت متناظر با حدت سابجکتیو (Subjective) نشان می دهد. با توجه به اهمیت پیش بینی میزان عیب انکساری بر اساس یافته های حدت بینایی، هدف از این بررسی پیش بینی عیب انکساری بر اساس حدت بینایی با استفاده از چارت اسنلن و دستگاه OPD-scan III در افراد با بینایی طبیعی می باشد. روش برر...

متن کامل

AcuTarget measurements: repeatability and comparison to OPD-Scan III.

PURPOSE To evaluate repeatability of the AcuTarget (SensoMotoric Instruments, Teltow, Germany) measurements and compare them to those obtained with the OPD-Scan III (NIDEK, Inc., Fremont, CA). METHODS Measurements were taken with the AcuTarget and OPD-Scan III in 62 eyes of 31 patients. Results were compared using paired Student's t tests, Pearson correlation coefficients, and 95% limits of a...

متن کامل

Presbyopia treatment by monocular peripheral presbyLASIK.

PURPOSE To investigate monocular peripheral presbyLASIK on the non-dominant eye with distance-directed monofocal refractive surgery on the dominant eye in treating presbyopia. METHODS One hundred three patients underwent treatment with a VISX S4 system and follow-up from 1.1 to 3.9 years (mean 27.4 months). Average patient age was 53.3 years. Preoperative refraction ranged from -9.75 to +2.75...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European review for medical and pharmacological sciences

دوره 20 14  شماره 

صفحات  -

تاریخ انتشار 2016