Correction of Partial volume Effects in Plasma Time Curve for Tracer Kinetic Analysis in DCE-MRI

نویسندگان

  • R. Rathore
  • A. Singh
  • R. Gupta
  • M. Haris
  • S. Verma
  • A. Purwar
  • G. Bayu
  • M. Sarma
  • J. Singh
  • S. Agarwal
  • D. Rathore
چکیده

INTRODUCTION: Tracer kinetic analysis of DCE-MRI data requires concentration of contrast agent (intravenously injected) in the plasma (as an input function). Both standard (8) and individually measured plasma concentration curves are being used. The use of individually measured plasma curve (if accurately measured) has advantages over standard plasma curve as it improves accuracy of measurements (4). Given a suitable image acquisition protocol (3, 5) the measurements of plasma curve is feasible, and was shown to be reproducible by Parker et al. 2003. Rijpkema et al., 2001 and Parker GJM, et al., 2003, 2006 used a semi-automatic selection criterion to find all ‘arterial’ voxels in brain images. In a brain DCE-MRI data the partial volume effect (PVE) is the main problem in the measurement of accurate plasma curve. Plasma curve measurements using the procedures described by Rijpkema et al., 2001 and Parker GJM, et al., 2003, 2006 suffers from PVE. This is mainly because of low spatial resolution of DCE-MRI data, due to which even a manual measurement suffers from PVE. In particular, PVE results in an underestimation of the amplitude of the plasma curve, due to which the tracer kinetic analysis (with and without intravascular term) in the high contrast enhancing regions can not be done accurately. The automated AIF extraction method proposed here is similar to that described by Rijpkema et al., 2001 and Parker et al., 2006, but it additionally corrects for the partial volume effect, and also does an automatic estimation of bolus arrival time (BAT) using PL model (2). Our procedure is fully automatic and does not require any operator interaction. We also compare the tracer kinetic analysis results from the present procedure with those obtained without the correction of PVE, and those from the standard plasma curve (8). MATERIALS AND METHODS: Patient and data acquisition: Fifteen patients with high grade gliomas were studied using a 1.5T GE scanner. DCE-MRI was performed using a 3D-SPGR sequence (TR/TE-5/1.4, flip angle-15o, The field of view (FOV) 360 х 270mm, slice thickness6mm, matrix size256 х 192.). At the 4 acquisition, Gd-DTPA at a dose of 0.2 mmol/kg of body weight was administered. A series of 384 images at 32 time points for 12 slices were acquired (≅ 5.25 s temporal resolution). As per our protocol (1) T1, T2, PD weighted FSE stacks (and an additional post contrast T1 weighted FSE stack for control purposes) for the same slice locations as chosen for the 3D SPGR were acquired. Method for automatic plasma curve measurement: Find BAT (using PL model fitting to C(t) (2)), peak value and time to peak (TTP) of each voxel’s C(t) of a given data set. After this, threshold out all pixels with time difference [TTP-BAT] >10 s, find the 95 percentile of peak values of the remaining voxels, followed by exclusion of all pixels with peak value below 95-th percentile. Find minimum of BAT’s (minBat) of the remaining voxels (arteries and veins). Finally all the voxels with BAT= minBat are the candidates for a choice of the plasma curves. Take average of all final candidate voxels to get an average plasma curve (take delay effects into account using BAT). Hematockrit label (0.4) was taken into account for obtaining the true plasma curve. The proposed new procedure to correct for PVE consists of using the relation: Corrected Cp(t) = (Cp(t)/max)*MAX, where max is the peak value of measured Cp(t) curve and MAX is the global peak value during the first pass over the entire data set (or the concentration at a pure plasma voxel). For the case reported below MAX equalled 6 mmol/L. This choice of MAX value was the computed maximum value observed during first pass over the entire data sets. Data processing: The data was processed using in-house developed perfusion software (based on JAVA programming language) (1). Images were registered using inhouse developed registration software for voxel wise analysis. Firstly voxel-wise tissue T10 was computed followed by conversion of S(t) into concentration time curve (C(t)) (1). BAT was estimated for each voxel using PL model (1) fitted to C(t) curve. Plasma curve was estimated for each patient using above described procedure and corrected for PVE. Generalized tracer kinetic model (GTKM) (inclusion of intravascular term to tracer kinetic model) (1, 4) was fitted to C(t). Fitting of GTKM to C(t) was carried out using least square minimization using Levenberg-Marquardt Method (Press et al 1997). Before fitting GTKM to C(t), hemotokrit level 0.4 was taken into account in plasma curve (Cp(t)). GTKM fitting was carried out using the earlier mentioned three different plasma curves.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of scatter coincidences, partial volume, positron range and non-colinearity on the quantification of FDOPA Patlak analysis

Introduction: The key characteristics of positron emission tomography (PET) are its quantitative capability and its sensitivity, which allow the in vivo imaging of biochemical interactions with small amounts of tracer concentrations. Therefore, accurate quantification is important. However, it can be sensitive to several physical factors. The aim of this investigation is the assessment of the e...

متن کامل

Automatic Prostate Cancer Segmentation Using Kinetic Analysis in Dynamic Contrast-Enhanced MRI

Background: Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) provides functional information on the microcirculation in tissues by analyzing the enhancement kinetics which can be used as biomarkers for prostate lesions detection and characterization.Objective: The purpose of this study is to investigate spatiotemporal patterns of tumors by extracting semi-quantitative as well as w...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

A synthetic data set for validation of tracer kinetic modelling and model-driven registration in DCE-MRI

G. A. Buonaccorsi, G. J. Parker Imaging science and Biomedical Engineering, University of Manchester, Manchester, Manchester, United Kingdom Introduction In clinical quantitative dynamic contrast enhanced MRI (DCE-MRI), it is difficult to verify the accuracy of estimates of kinetic model parameters such as K, ve and vp, as we do not know the ‘true’ parameter values (ground truth). The problem i...

متن کامل

Dynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors

Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007