The Structure Superposition Database

نویسندگان

  • Ranyee A. Chiang
  • Elaine C. Meng
  • Conrad C. Huang
  • Thomas E. Ferrin
  • Patricia C. Babbitt
چکیده

The need for new tools for investigating biological systems on a large scale is becoming acute, particularly with respect to computationally intensive analyses such as comparisons of many three-dimensional protein structures. Structure superposition is a valuable approach for understanding evolutionary relationships and for the prediction of function. But while available tools are adequate for generating and viewing superpositions of single pairs of protein structures, these tools are generally too cumbersome and time-consuming for examining multiple superpositions. To address this need, we have created the Structure Superposition Database (SSD) for accessing, viewing and understanding large sets of structure superposition data. The initial implementation of the SSD contains the results of pairwise, all-by-all superpositions of a representative set of 115 (beta/alpha)8 barrel structures (TIM barrels). Future plans call for extending the database to include representative structure superpositions for many additional folds. The SSD can be browsed with a user interface module developed as an extension to Chimera, an extensible molecular modeling program. Features of the user interface module facilitate viewing multiple superpositions together. The SSD interface module can be downloaded from http://ssd.rbvi.ucsf.edu.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved drain current characteristics of tunnel field effect transistor with heterodielectric stacked structure

In this paper, we proposed a 2-D analytical model for electrical characteristics such as surface potential, electric field and drain current of Silicon-on-Insulator Tunnel Field Effect Transistor (SOI TFETs) with a SiO2/High-k stacked gate-oxide structure. By using superposition principle with suitable boundary conditions, the Poisson’s equation has been solved to model the channel r...

متن کامل

Evaluating Performance of Algorithms in Lung IMRT: A Comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms

Background: Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.Objective: In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy plannin...

متن کامل

Challenges in Protein Structure Prediction and Drug Discovery

Alignment or superposition of multiple flexible ligands in 3D is a key step in rational ligand-based drug design, pharmacophore elucidation and 3D QSAR analysis. We have recently introduced Atomic Property Fields methodology, which utilizes continuous Gaussian-based multicomponent potentials to represent the distributions of physico-chemical atomic properties. Calculation of APF pseudo-energy p...

متن کامل

An Entanglement Study of Superposition of Qutrit Spin-Coherent States

Considering generalized concurrence as the criterion of entanglement, we study entanglement properties of superposition of two qutrit coherent states, as a function of their amplitudes. These states may attain maximum entanglement or no entanglement at all, depending on the choice of the parameters involved. The states revealing maximum entanglement also display the maximum violations of the Be...

متن کامل

Point Dose Measurement for Verification of Treatment Planning System using an Indigenous Heterogeneous Pelvis Phantom for Clarkson, Convolution, Superposition, and Fast Superposition Algorithms

Background: Nowadays, advanced radiotherapy equipment includes algorithms to calculate dose. The verification of the calculated doses is important to achieve accurate results. Mostly homogeneous dosimetric phantoms are available commercially which do not mimic the actual patient anatomy; therefore, an indigenous heterogeneous pelvic phantom mimicking actual human pelvic region has been used to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nucleic acids research

دوره 31 1  شماره 

صفحات  -

تاریخ انتشار 2003