Otago glaucoma surgery outcome study: cytology and immunohistochemical staining of bleb capsules around Molteno implants.

نویسندگان

  • Anthony C B Molteno
  • Antony J Suter
  • Mark Fenwick
  • Tui H Bevin
  • Alex G Dempster
چکیده

PURPOSE To describe the cytology and immunohistochemistry of Molteno implant capsules from cases of primary and secondary glaucoma. METHODS Histologic features of capsules including cell cytology, the distribution of activated (proliferating) cells, apoptosing cells, and membrane bound vesicles (presumed death messengers) were assessed by light microscopy and correlated with clinicopathological features in 10 noninflamed eyes with good intraocular pressure control (nine autopsy and one enucleation) obtained from 2 months to 16.8 years after insertion of Molteno implants. RESULTS All bleb capsules demonstrated two distinct layers. The thin external layer was cellular with fairly numerous small blood vessels coursing through normally staining, regularly arranged collagen fibers. The thicker, deeper layer was avascular, relatively acellular, and characterized by regularly arranged swollen and fragmented collagen fibers. Most cells in the external layer appeared normal; however, between 5% (in recently formed blebs) and approximately 50% (in well established blebs) showed cytological and/or immunohistochemical changes characteristic of metabolic activation and/or apoptosis. All cells in the deeper layer, regardless of time after surgery, also demonstrated cytological and/or immunohistochemical staining characteristic of metabolic activation and/or apoptosis. In addition, the deeper layer evidenced large numbers of minute membrane-bound vesicles (presumed death messengers). CONCLUSIONS The balance between activation and apoptosis regulates the thickness and permeability of bleb capsules, and the normal lifecycle of bleb capsules includes continual inner surface degeneration and external surface renewal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Otago Glaucoma Surgery Outcome Study: long term results of cataract extraction combined with Molteno implant insertion or trabeculectomy in primary glaucoma.

BACKGROUND/AIMS To describe the long term results of cases of cataract extraction combined with either Molteno implant insertion or trabeculectomy for primary open angle glaucoma. METHODS This prospective case series followed cases which had cataract extraction and Molteno implant insertion (45 eyes) or trabeculectomy (94 eyes) followed up for a mean of 5.3 years and 3.9 years respectively. ...

متن کامل

SCIENTIFIC REPORT Otago Glaucoma Surgery Outcome Study: long term results of cataract extraction combined with Molteno implant insertion or trabeculectomy in primary glaucoma

Background/Aims: To describe the long term results of cases of cataract extraction combined with either Molteno implant insertion or trabeculectomy for primary open angle glaucoma. Methods: This prospective case series followed cases which had cataract extraction and Molteno implant insertion (45 eyes) or trabeculectomy (94 eyes) followed up for a mean of 5.3 years and 3.9 years respectively. R...

متن کامل

Long-term results of Molteno implant insertion in cases of neovascular glaucoma.

OBJECTIVE To describe the long-term outcomes of cases of neovascular glaucoma drained by Molteno implants. METHODS A prospective study of 145 eyes (130 patients) followed up for a mean of 3.3 years (range, 0.02 year [5 days] to 18.1 years) in the province of Otago, New Zealand, from 1979 to 2002. RESULTS Insertion of a Molteno implant controlled the intraocular pressure at 21 mm Hg or less ...

متن کامل

Update on Tube-Shunt Procedures for Glaucoma

Present-day glaucoma implants, i.e., long-tube implants, were introduced by Molteno et al. in 1976 [31]. !e most commonly used implants include Molteno and Ahmed singleand doubleplate implants, and the Baerveldt and Krupin implants. All implants are long-tube implants based on the original Molteno design. !e Ahmed and Krupin implants are valved implants. !e most recent addition to tube-shunt de...

متن کامل

Otago glaucoma surgery outcome study: comparative results for the 175-mm2 Molteno3 and double-plate molteno implants.

OBJECTIVE To evaluate the efficacy of the 175-mm2 Molteno3 implant in patients with nonneovascular glaucoma. METHODS A hospital-based, retrospective historical control comparative case series comparing results in the first 87 eyes to receive the 175-mm(2) Molteno3 implant with those in a control group of 115 eyes receiving the 274-mm(2) double-plate Molteno implant. RESULTS Success was defi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 47 5  شماره 

صفحات  -

تاریخ انتشار 2006