Experimental Comparison of High Duty Cycle and Pulsed Active Sonars in a Littoral Environment
نویسندگان
چکیده
Military sonars must detect, localize, classify, and track submarine threats from distances safely outside their circle of attack. However, conventional pulsed active sonars (PAS) have duty cycles on the order of one percent which means that 99% of the time, the track is out of date. In contrast, high duty cycle sonars (HDC) have duty cycles approaching 100% which enable near-continuous updates to the track. If one can overcome technical challenges such as the high dynamic range required by the receiver, then HDC should significantly improve tracking performance in the free-field environment that one encounters (approximately) in the deep ocean; however, improvements in tracking performance in shallow water are not assured since both targets and clutter will be tracked continuously and HDC may increase false tracks to an unacceptably high level – essentially continuously tracking the clutter. Theoretical predictions of performance are challenging since the reverberation background for shallow water HDC has not been accurately modeled. To compare performance of HDC with conventional PAS in the littorals, a set of experiments were conducted as part of the Target and Reverberation Experiment (TREX) in spring 2013. This was the first scientifically controlled experiment conducted in the littorals to compare the environmental effects on these two approaches to active sonar. In this project the data from TREX will be analyzed to provide a quantitative comparison of the impact of the environment on the two techniques.
منابع مشابه
15: Experimental Comparison of High Duty Cycle and Pulsed Active Sonars in a Littoral Environment
Military sonars must detect, localize, classify, and track submarine threats from distances safely outside their circle of attack. However, conventional pulsed active sonars (PAS) have duty cycles on the order of one percent which means that 99% of the time, the track is out of date. In contrast, high duty cycle sonars (HDC) have duty cycles approaching 100% which enable near-continuous updates...
متن کامل14: Experimental Comparison of High Duty Cycle and Pulsed Active Sonars in a Littoral Environment
Military sonars must detect, localize, classify, and track submarine threats from distances safely outside their circle of attack. However, conventional pulsed active sonars (PAS) have duty cycles on the order of one percent which means that 99% of the time, the track is out of date. In contrast, high duty cycle sonars (HDC) have duty cycles approaching 100% which enable near-continuous updates...
متن کاملMD-Simulation of Duty Cycle and TaN Interlayer Effects on the Surface Properties of Ta Coatings Deposited by Pulsed-DC Plasma Assisted Chemical Vapor Deposition
In this work, molecular dynamics (MD) simulations were employed to investigate the effects of duty cycle changes and utilization of tantalum nitride interlayer on the surface roughness and adhesion of Ta coating deposited by pulsed-DC plasma assisted chemical vapor deposition. To examine the simulation results, some selected deposition conditions were experimentally implemented and characterize...
متن کاملINVESTIGATION NITRIDE LAYERS AND PROPERTIES SURFACES ON PULSED PLASMA NITRIDED HOT WORKING STEEL AISI H13
Nitriding is a surface treatment technique used to introduce nitrogen into metallic materials to improve their surface hardness, mechanical properties, wear resistance and corrosion resistance. In this research, the effects of plasma nitriding parameters including frequency and duty cycle were investigated on samples with different grooves dimensions. Steel blocks prepared from DIN1.2344 hot wo...
متن کاملEffect of pulsed current densities on co-electrodeposition of Graphene Oxide/ Calcium-Phosphate coatings and their biocompatibility
In this study, calcium-phosphate (Ca-P) and graphene oxide (GO)/ calcium-phosphate (Ca-P) coatings were electrodeposited with different pulsed current densities on TiO2 nanotubes. Results showed that the co-electrodeposition rate in the presence of GO, especially at low current densities of 2 and 5 mA/cm2, significantly decreased. This might be due to the large size of GO sheets as compared to ...
متن کامل