Retrospective respiratory motion correction for navigated cine velocity mapping.
نویسندگان
چکیده
In general, high spatial and temporal resolutions in cine cardiac imaging require long scan times, making breath-hold acquisition impossible in many cases. To enable free-breathing cardiac imaging, methods such as navigator gating were developed to reduce image artifacts due to respiratory motion. Nevertheless, residual image blurring is seen in images acquired late in the cardiac cycle. Image blurring itself hampers accurate blood flow quantification, especially in vessels exhibiting high flows during diastole. In the present work, the navigator gating and slice tracking method was extended by using navigator information to correct for in-slice motion components throughout the cardiac cycle. For this purpose, a standard two-dimensional (2D) cine phase contrast sequence with navigator gating and slice position correction was used, and navigator information was recorded along with the raw k-space data. In postprocessing, in-plane motion components arising from respiration during the actual data acquisition were estimated and corrected according to the Fourier shift theorem. In phantom experiments, the performance of the correction algorithm for different slice angulations with respect to the navigator orientation was validated. In vivo, coronary flow measurements were performed in 9 healthy volunteers. The correction algorithm led to considerably improved vessel sharpness throughout the cardiac cycle in all measured subjects [increase in vessel sharpness: 16+/-11% (mean+/-SD)]. Furthermore, these improvements resulted in increased volume flow rates [16+/-13% (mean+/-SD)] after retrospective correction indicating the impact of the method. It is concluded that retrospective respiratory motion corrections for navigated cine two-dimensional (2D) velocity mapping can correct for in-plane motion components, providing better image quality for phases acquired late in the cardiac cycle. Therefore, this method holds promise in particular for free-breathing coronary flow quantification.
منابع مشابه
Free-breathing 2D Cine DENSE with Localized Excitation, Self-navigation and Motion Correction
Background Cine DENSE MRI is an established myocardial strain imaging technique with high accuracy and rapid data analysis. Current cine DENSE protocols utilize breathholding (BH); however, this practice limits the use of this technique to patients with good BH capabilities, excluding many pediatric and some heart failure patients. We propose a free-breathing (FB) framework for cine DENSE that ...
متن کاملMouse cardiac MRI: comparison of prospective synchronization using optical and ECG signals with a retrospective technique
Introduction Prospective synchronization on living organisms of MRI acquisitions to reduce the motion artifacts involves the monitoring of both respiratory and heart motions in the thorax and abdominal region. The signal conventionally used to measure cardiac cycle is the electrocardiograph (ECG) signal. Respiratory motion can be derived from low frequency modulation of ECG signal [1]. Because ...
متن کاملCine CT for attenuation correction in cardiac PET/CT.
UNLABELLED In dual-modality PET/CT systems, the CT scan provides the attenuation map for PET attenuation correction. The current clinical practice of obtaining a single helical CT scan provides only a snapshot of the respiratory cycle, whereas PET occurs over multiple respiratory cycles. Misalignment of the attenuation map and emission image because of respiratory motion causes errors in the at...
متن کاملComprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance
BACKGROUND Phase contrast cardiovascular magnetic resonance (CMR) is able to measure all three directional components of the velocities of blood flow relative to the three spatial dimensions and the time course of the heart cycle. In this article, methods used for the acquisition, visualization, and quantification of such datasets are reviewed and illustrated. METHODS Currently, the acquisiti...
متن کامل3D free-breathing cardiac cine imaging with respiratory and cardiac self-gating and 3D motion correction
INTRODUCTION Free-breathing cardiac cine imaging with respiratory and cardiac self-gating provides flexibility and convenience for patient scans. Here we propose a 3D radial cardiac cine imaging technique that improves upon self-gating by adding 3D respiratory motion correction. The 3D respiratory motion signals are derived from multiple projections through the data used for image reconstructio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
دوره 6 4 شماره
صفحات -
تاریخ انتشار 2004